Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK in 499 JEFFERSON ST, SAN FRANCISCO, CA 94109 (NAICS 712120). OSHA activity number 347178915.

Watch U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park — free Get an email when a new federal OSHA severe-injury report for U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park is published. One employer, no account, unsubscribe in one click.
Site address
499 JEFFERSON ST
City
SAN FRANCISCO
State
CA
ZIP
94109
Mailing
2 MARINA BLVD BLDG E, SAN FRANCISCO, CA 94123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712120
Employees
70
Ownership type
D

12 citations on file for this inspection.

1910.22 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.22(d)(1): The employer did not ensure that walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition:  On the lower deck of the ship Balclutha, there were large gaps in the floor planking and uneven walking/working surfaces. One section of the walking working surface had exposed stone with a single plank across it. Employees were exposed to heights and potential falls into the gaps.
Recent events (1)
  • — Z (S) $0

1910.184 C06

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.184(c)(6): Slings were not securely attached to their loads:  Outside of the small crafts work shop on the Hyde St. Pier, a small craft was being held up by slings. A purple synthetic web sling was affixed to a rod at the bow in a way that it could slip off of the rod if the load shifted or was moved. Employees are exposed to potential falling loads.
Recent events (1)
  • — Z (S) $0

1910.184 C14

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 4, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.184(c)(14):  Employers used slings without affixed and legible identification markings.  Outside the small crafts workshop, a purple synthetic sling on the stern of a small craft was in use. The sling identification tag was worn off and illegible.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 8 instances 5 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks:  Museum Building Boiler room: The machine guard over a rotating belt connected to a NIDEC motor, catalog # D5P20, did not fully enclose the in-going nip points or the end of the rotating belt.   Exhibits Room: A green Woodtek drill press did not have a guard at the point of operation (chuck).  BMU Facilities: 1). A green Wells Index milling machine did not have a guard at the point of operation.  2). A Grizzly Industries model G0709 lathe did not have a guard at the point of operation or over rotating parts. 3). A green Powermatic brand, model no. 1200, drill press did not have a guard at the point of operation (chuck).  Shipwright Shop at Hyde Street Pier A Delta Rockwell drill press did not have a guard at the point of operation (chuck).   Small Crafts Workshop at Hyde Street Pier: 1). Clausing lathe did not have any machine guarding over the in-going nip points of a rotating belt nor at the point of operation. 2). Powermatic drill press serial no. 11063454 did not have a guard at the point of operation (chuck).   Employees are exposed to potential contact with rotating parts or flying objects, which can cause eye injuries, lacerations, or amputations.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  In the Exhibits Workshop, the Woodtek drill press, serial no. 1159048 was not securely anchored to prevent walking or moving during use. Machines such as drill presses can tip over when in use if they are not securely anchored.
Recent events (1)
  • — Z (S) $0

1910.213 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.213(c)(1): Circular hand-fed ripsaw(s) were not guarded by an automatically adjusting hood, which completely enclosed that portion of the saw above the table and above the material being cut:  At the shipwright carpentry shop on the Hyde Street Pier, a table saw was not guarded by an automatically adjusting hood that completely encloses the portion of the saw above the table.
Recent events (1)
  • — Z (S) $0

1910.213 I01

Serious Gravity 5 3 instances 3 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.213(i)(1): Non-working portions of the blade of bandsaws were not enclosed or guarded:  1). Exhibits area wood shop: The non-working portions of the blade of a Delta bandsaw, model number 28-206, serial number 302648, were not fully enclosed or guarded. The blade portion next to the Start/Stop button was not fully enclosed. There was a gap in the enclosure at the front of the blade.   2). Hyde Street Pier, Shipwright Shop: The non-working portions of the blade of a Delta bandsaw, series number 15-665, serial number 1491601, were not fully enclosed or guarded. The blade portion next to the Start/Stop button was not fully enclosed. There was a gap in the enclosure at the front of the blade.   3). Small Crafts Area: The blade portion next to the Start/Stop button was not fully enclosed on a green Delta band saw. There was a gap in the enclosure at the front of the blade.   Employees are exposed to potential severe lacerations or amputation of fingertips.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii): Where there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made:  In the Exhibits Workshop, a DeWalt electronic plunge cut router, model no. DW 625, serial no. 069704, had a nick in the cord that exposed the internal components. Employees were exposed to potential contact with electricity which can cause shock.
Recent events (1)
  • — Z (S) $0

1915.71 C07

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1915.71(c)(7): The minimum dimensions and spacing of members of independent pole wood scaffolding were not in accordance with section 1915.118 Table E-1.   On the historical ship Eureka, 2x2 pieces of lumber were being used as center vertical supports for a shipwright scaffold. The 2x2s were stacked on top of other pieces of lumber including wedges on top of a sawhorse. The scaffold was at the top of the stairs of the Eureka and potentially unstable. Employees were exposed to a fall hazard.
Recent events (1)
  • — Z (S) $0

1910.179 J02 IV

Other-than-serious 3 instances 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.179(j)(2)(iv): Hoist chains were not inspected monthly with a certification record which included the date of the inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected:  Located at the Hyde Street Pier, hoist chains on the gantry crane outside the small crafts shop were not inspected monthly with a certification record that contained all required elements. The hoist chains included 3 ton magna type hoist and Dayton hand chain hoist model 1VW59.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):Listed or labeled equipment was not installed and used in accordance with instructions included in the listing and labeling.  In the museum building, exhibits area, a Fellowes relocatable power tap (power strip) was being used to power a Chefmate microwave, model WP700AP20-6, and a refrigerator. Employees were exposed to potential electric shock from using equipment in a manner not recommended by the manufacturer.
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 7 exposed
Issued
Mar 11, 2024
Abate by
Dec 31, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:  The employer's hazard communication plan did not include a list of the hazardous chemicals known to be present at the facility.
Recent events (4)
  • — P (O) $0
  • — P (O) $0
  • — P (O) $0

View U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347178915.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.