Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK in 2435 POLVOROSA AVE, SAN LEANDRO, CA 94577 (NAICS 712120). OSHA activity number 347183485.

Watch U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park — free Get an email when a new federal OSHA severe-injury report for U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park is published. One employer, no account, unsubscribe in one click.
Site address
2435 POLVOROSA AVE
City
SAN LEANDRO
State
CA
ZIP
94577
Mailing
2 MARINA BLVD BLDG E, SAN FRANCISCO, CA 94123
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
712120
Employees
10
Ownership type
D

6 citations on file for this inspection.

1910.176 B

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.176(b): Storage of material created a hazard. Bags, containers, bundles., etc, stored in tiers were not stacked, blocked, interlocked, or limited in height so that they were stable and secured against sliding or collapsing.  Located at the San Leandro warehouse in zone 24, storage of wood created a hazard. In front of the sign for zone 24 on a wheeled cart, large blocks of timber were unevenly stacked in excess of 6' high without being tied down or otherwise secured.
Recent events (1)
  • — Z (S) $0

1910.178 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:   At the San Leandro Warehouse, forklift attachments were used without prior written approval from the forklift manufacturer. Attachments included:  1). Star Industries Fork Mounted Lift N Tow Model Number 1390B 2). Fork Extensions  Attachment use can alter the forklift's capacity or load center. Employees are exposed to potential crushing injuries from machine tipover or falling loads.
Recent events (1)
  • — Z (S) $0

1910.184 I09 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2024
Abate by
Mar 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears or cuts were not immediately removed from service.  At the San Leandro warehouse, a 3-inch Lift-All Nylon web sling, type EN2-803, had a tear that exposed the inner material. Employees were exposed to potential crushing injuries from dropped loads.
Recent events (1)
  • — Z (S) $0

1910.213 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded:  At the San Leandro warehouse in Zone 23, the non-working portions of the blade of a Delta vertical bandsaw used on wood was not fully enclosed or guarded.   Employees are exposed to potential amputation hazards from contact with the saw blade.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Other-than-serious 2 instances 2 exposed
Issued
Mar 11, 2024
Abate by
Jun 28, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   At the San Leandro warehouse, portable fire extinguishers had not had annual maintenance checks done within the last year. Extinguishers throughout the building had not been inspected since September 16, 2022. One extinguisher in the fire rated hazardous material storage area had not had an annual maintenance since 2012.
Recent events (3)
  • — P (O) $0
  • — P (O) $0
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 2 instances 2 exposed
Issued
Mar 11, 2024
Abate by
Apr 25, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(ii): Where there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made:  At the San Leandro warehouse, two pieces of equipment had evidence of defects or damage in the electrical cords that could expose employees to injuries.  1). The outer cord sleeve of a yellow Fostoria Industries tower work light was damaged, exposing the wiring underneath at the connection point of the cord to the outlet receptacle fixed to the light.  2). The plug on a second yellow Fostoria Industries tower work light had scorch marks on it.
Recent events (1)
  • — Z (O) $0

View U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347183485.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.