SAN LEANDRO, CA —
OSHA Inspection: U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK in 2435 POLVOROSA AVE, SAN LEANDRO, CA 94577 (NAICS 712120). OSHA activity number 347183485.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF THE INTERIOR - NATIONAL PARK SERVICE - SAN FRANCISCO MARITIME NATIONAL HISTORICAL PARK
- Site address
- 2435 POLVOROSA AVE
- City
- SAN LEANDRO
- State
- CA
- ZIP
- 94577
- Mailing
- 2 MARINA BLVD BLDG E, SAN FRANCISCO, CA 94123
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712120
- Employees
- 10
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.176 B
- Issued
- Mar 11, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard. Bags, containers, bundles., etc, stored in tiers were not stacked, blocked, interlocked, or limited in height so that they were stable and secured against sliding or collapsing. Located at the San Leandro warehouse in zone 24, storage of wood created a hazard. In front of the sign for zone 24 on a wheeled cart, large blocks of timber were unevenly stacked in excess of 6' high without being tied down or otherwise secured.
Recent events (1)
- — Z (S) $0
1910.178 A04
- Issued
- Mar 11, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: At the San Leandro Warehouse, forklift attachments were used without prior written approval from the forklift manufacturer. Attachments included: 1). Star Industries Fork Mounted Lift N Tow Model Number 1390B 2). Fork Extensions Attachment use can alter the forklift's capacity or load center. Employees are exposed to potential crushing injuries from machine tipover or falling loads.
Recent events (1)
- — Z (S) $0
1910.184 I09 III
- Issued
- Mar 11, 2024
- Abate by
- Mar 28, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears or cuts were not immediately removed from service. At the San Leandro warehouse, a 3-inch Lift-All Nylon web sling, type EN2-803, had a tear that exposed the inner material. Employees were exposed to potential crushing injuries from dropped loads.
Recent events (1)
- — Z (S) $0
1910.213 I01
- Issued
- Mar 11, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(i)(1): Non-working portion(s) of the blade of bandsaw(s) were not enclosed or guarded: At the San Leandro warehouse in Zone 23, the non-working portions of the blade of a Delta vertical bandsaw used on wood was not fully enclosed or guarded. Employees are exposed to potential amputation hazards from contact with the saw blade.
Recent events (1)
- — Z (S) $0
1910.157 E03
- Issued
- Mar 11, 2024
- Abate by
- Jun 28, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: At the San Leandro warehouse, portable fire extinguishers had not had annual maintenance checks done within the last year. Extinguishers throughout the building had not been inspected since September 16, 2022. One extinguisher in the fire rated hazardous material storage area had not had an annual maintenance since 2012.
Recent events (3)
- — P (O) $0
- — P (O) $0
- — Z (O) $0
1910.334 A02 II
- Issued
- Mar 11, 2024
- Abate by
- Apr 25, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): Where there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made: At the San Leandro warehouse, two pieces of equipment had evidence of defects or damage in the electrical cords that could expose employees to injuries. 1). The outer cord sleeve of a yellow Fostoria Industries tower work light was damaged, exposing the wiring underneath at the connection point of the cord to the outlet receptacle fixed to the light. 2). The plug on a second yellow Fostoria Industries tower work light had scorch marks on it.
Recent events (1)
- — Z (O) $0
More inspections at U.S. Department OF THE Interior - National Park Service - SAN Francisco Maritime National Historical Park
More inspections in this industry (NAICS 712120)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347183485.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.