Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY MACHINING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of QUALITY MACHINING, LLC in 2400 INDUSTRIAL RD., SAPULPA, OK 74066 (NAICS 332410). OSHA activity number 347213100.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Machining, LLC — free Get an email when a new federal OSHA severe-injury report for Quality Machining, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2400 INDUSTRIAL RD.
City
SAPULPA
State
OK
ZIP
74066
Mailing
2400 INDUSTRIAL RD., SAPULPA, OK 74066
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
45
Ownership type
A

14 citations on file for this inspection.

1910.106 E02 II B 2

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $9,680 · Current $5,000 Reduced
29 CFR 1910.106(e)(2)(ii)(b)(2): More than 120 gallons of Category 2, 3, or 4 flammable or combustible liquids in containers were located outside of inside storage room(s) or storage cabinet(s).  On or about January 10, 2024 and at times prior thereto, near spraying area, employees worked in areas where more than 120 gallons of category 2 and 3 flammable chemicals are stored on open shelves in the building.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9680

1910.107 E02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $8,067 · Current $0 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift.  On or about January 10, 2024 and at times prior thereto, in the chemical mixing area of the spraying area, employees obtained and mixed chemicals in an area where more than a days amount of chemicals was being stored.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.106 H07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $8,067 · Current $3,800 Reduced
29 CFR 1910.106(h)(7)(i)(a):  Precautions were not taken to prevent the ignition of flammable vapors.  On or about January 10, 2024 and at times prior there to, in the chemical mixing area of the spraying area, an electric space heater was mounted in the ceiling and in use where employees obtain and mix chemicals.
Recent events (2)
  • — I (S) $3800
  • — Z (S) $8067

1910.107 G02

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $8,067 · Current $3,800 Reduced
29 CFR 1910.107(g)(2): Spraying area(s) were not kept free from the accumulation of deposits of combustible residues and tool(s) used for cleaning purposes in spraying area(s) were not of non-sparking material.  On or about January 10, 2024 and at times prior thereto, in the spraying area, employees were performing spraying operations where a large amount of spraying residue was observed accumulated on surfaces in the spray booth.
Recent events (2)
  • — I (S) $3800
  • — Z (S) $8067

1910.184 E01

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $9,680 · Current $4,300 Reduced
29 CFR  1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach.                                                                                                                                                                                                                                                                                                   On or about January 10, 2024, an employee was in use of an alloy steel sling that did not have permanently affixed identification stating its rating and capabilities.
Recent events (2)
  • — I (O) $4300
  • — Z (S) $9680

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $9,680 · Current $5,000 Reduced
29 CFR  1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields.                                                                                                                                                                                                                                                                                                                                                                                           On or about January 10, 2024 and at times prior thereto, in the welding area, employees were performing welding operations in areas were adjacent employees are not protected from the rays by noncombustible or flameproof screens or shields.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $9680

1910.253 B04 III

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $9,680 · Current $4,300 Reduced
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.   On or about January 10, 2024 and at times prior thereto, in the cylinder storage area, oxygen and propane cylinders were stored together in the cylinder storage cages.
Recent events (2)
  • — I (O) $4300
  • — Z (S) $9680

1910.303 G01

Serious Gravity 5 7 instances 6 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $8,067 · Current $3,800 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  On or about January 10, 2024, in the welding area and side frames area, the working space around multiple electrical panels in use were blocked.
Recent events (2)
  • — I (S) $3800
  • — Z (S) $8067

1910.305 B02 I

Serious Gravity 1 3 instances 1 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR  1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.  a.)  On or about January 10, 2024, in the saw area, an electric wall box was not equipped with a cover.  b.)  On or about January 10, 2024, in an aisle leading to the main east exit, the cover to an electric wall box was missing a screw and hanging from the bottom of the junction box.    c.)  On or about January 10, 2024, in welding booth #5, the cover to an electric wall box was not effectively closed and the cover was missing a screw and pushed to the side with wires outside of the box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4839

1910.305 G01 IV A

Serious Gravity 5 4 instances 6 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $8,067 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A):  Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.                                                                                                                          On or about January 10, 2024, extension cords (flex wiring) were observed used as a substitute for fixed wiring:  a.)  By the main east door, an extension cord, used to provide power to a light fixture, was zip-tied to conduit.      b.)  In the spraying area, an extension cord, used to provide power to a space heater, was zip-tied to conduit.      c.)  In the saw area, an extension cord was wrapped behind beams.        d.)  In the CNC area, an extension cord, used to provide power to cameras, was wrapped around beams.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8067

1910.157 C01

Other-than-serious 2 instances 3 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.    a.)  On or about January 10, 2024, by the main east door at the facility, a fire extinguisher was mounted but did not have a marking indicating the location of the fire extinguisher.     b.)  On or about January 10, 2024, in the CNC area at the facility, a fire extinguisher was mounted but did not have a marking indicating the location of the fire extinguisher.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.254 C02 V

Other-than-serious 1 instance 1 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.254(c)(2)(v): All ground connections were not checked to determine that they were mechanically strong and electrically adequate for the required welding current.  On or about January 10, 2024, in welding bay #3, an employee used a Miller welding machine with a grounding connection that had exposed damaged copper wires.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 E01 II

Other-than-serious 3 instances 3 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(ii): Markings giving voltage, current, wattage, or other ratings was not on electrical equipment.  a.)  On or about January 10, 2024, in the saw area at the facility, an electrical panel was observed without markings indicating voltage or other ratings.    b.)  On or about January 10, 2024, in the CNC area at the facility, an electrical panel was observed without markings indicating voltage or other ratings.    c.)  On or about January 10, 2024, in the CNC area at the facility, an electrical panel was observed without markings indicating voltage or other ratings.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06

Other-than-serious 2 instances 3 exposed
Issued
Jul 2, 2024
Abate by
Jul 29, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section.  On or about January 10, 2024, by the main east doors at the facility, hanging from conduit were two spray bottles containing a liquid were not properly labeled.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Quality Machining, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347213100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.