Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: PACIFIC SHIPYARDS INTERNATIONAL, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PACIFIC SHIPYARDS INTERNATIONAL, LLC in HO'OLA I NA MOKU FLOATING DRY DOCK AT PIER 24 PIER 24 PRODUCTION AREAS, HONOLULU, HI 96817 (NAICS 336611). OSHA activity number 347279119.

Watch Pacific Shipyards International, LLC — free Get an email when a new federal OSHA severe-injury report for Pacific Shipyards International, LLC is published. One employer, no account, unsubscribe in one click.
Site address
HO'OLA I NA MOKU FLOATING DRY DOCK AT PIER 24 PIER 24 PRODUCTION AREAS
City
HONOLULU
State
HI
ZIP
96817
Mailing
705 N. NIMITZ HWY 1ST FLOOR, HONOLULU, HI 96817
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
50
Ownership type
A

11 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Penalty
Initial $8816.00 · Current $5290.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  A. On February 20, 2024, main production building: The Global Industrial drill press was operated without a chuck guard.  Employees were exposed to rotating part hazards.  B. On February 20, 2024, main production building: The Southwestern Industries, Inc. Trak DPMRX7 Milling machine, was operated without a chuck guard.  Employees were exposed to rotating part hazards.  C. On February 20, 2024, secondary production tent: The 16" Lodge & Shipley Model "A" lathe was operated without a chuck guard.  Employees were exposed to rotating part hazards.
Recent events (2)
  • — I (S) $5289.6
  • — Z (S) $8816

1910.212 A03 IV E

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(a)(3)(iv)(e): Employee(s) were using milling machines without point of operation guarding in place.  On February 20, 2024, main production building: The Trak DPM RX7 Milling machine was being operated without a guard at the point of operation.  Employees were exposed to laceration and rotating parts hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $10578.00 · Current $6347.00 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  On February 20, 2024, carpenter's shop: The blade above the table portion of the Delta Unisaw table saw used to cut plywood was not guarded during use.  Employees were exposed to laceration and amputation hazards.
Recent events (2)
  • — I (S) $6346.8
  • — Z (S) $10578

1910.213 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:  On February 20, 2024, carpenter's shop: the Delta Unisaw table saw used to cut plywood did not have a spreader to prevent the stock being cut from being thrown back on the operator. Employees were exposed to struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $7052.00 · Current $0.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On February 20, 2024, main production building, at east CNC lathe in Air Compression Station #6: An employee used the compressed air hose from the wall to clean himself of metal shards, with 118 p.s.i. compressed air coming from the air compressor and no chip guarding.  Employee was exposed to embolism and struck by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7052

1910.213 I01

Repeat Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $16592.00 · Current $9955.00 Reduced
29 CFR 1910.213(i)(1): Nonworking portion(s) of the blade of the band saw were not enclosed or guarded.  On February 20, 2024, main production building at Compressed Air Station #1: The Hydmech S-23P band saw blade guard was not adjusted to the size of the material being cut. Employees were exposed to cut and laceration hazards.  Pacific Shipyards International was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1487208, citation number 1, item number 1 and was affirmed as a final order on October 27, 2020, with respect to a workplace located at Pier 24.
Recent events (2)
  • — I (R) $9955.2
  • — Z (R) $16592

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  On February 13, 2024, Army Barge Essayons, Void 10: Two 100-foot extension cords were connected in a series "daisy chained" providing power to temporary lighting inside the void.  Employees were exposed to electrical and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV C

Other-than-serious 1 instance 15 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were used where run through doorways, windows, or similar openings:   On February 20, 2024, pier side paint area, next to temporary blasting booth: An extension cord powering a string of LED lights was pinched at the metal door corner to the Conex container that contained the paints used for ship repair projects.  Employees were exposed to electrical and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 II

Other-than-serious 2 instances 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:  On February 13, 2024, Army Barge Essayons, top forward deck: Two extension cords were spliced together to hard-wire two small heaters used to prevent condensation for the vessel's two wench motors.  Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  On February 20, 2024, carpenter's shop: The electrical cord connecting the on/off button to the Delta Unisaw table saw was damaged and cut, exposing live conductors.  Employees were exposed to electrical shock and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1915.81 B01 IV D

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.81(b)(1)(iv)(D): While a walkway or part of a walkway was being used as a working surface, the employer did not cordon off that portion to prevent pedestrian traffic from entering the area.   On February 13, 2024, Army Vessel Dredge Essayons, port side upper deck above Void 10: The part of the walkway being repaired that did not have deck covering was not blocked off to prevent access to pedestrians.  Employees were exposed to slip, trip and fall hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View PACIFIC SHIPYARDS INTERNATIONAL, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347279119.