Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KINNEY MANUFACTURING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KINNEY MANUFACTURING, LLC in 3440 GLADSTONE, LINCOLN, NE 68504 (NAICS 332710). OSHA activity number 347357543.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kinney Manufacturing, LLC — free Get an email when a new federal OSHA severe-injury report for Kinney Manufacturing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3440 GLADSTONE
City
LINCOLN
State
NE
ZIP
68504
Mailing
3340 NORTH 33RD STREET, LINCOLN, NE 68504
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
117
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Aug 16, 2024
Abate by
Sep 30, 2024
Penalty
Initial $6,844 · Current $4,449 Reduced
29 CFR 1910.134(c)(1): The respiratory protection program was not updated as necessary to reflect those changes in workplace conditions that affected respirator use:   On or about March 27, 2024, it was documented that employees engaged in laser activities in the south building of Kinney Manufacturing, LLC, dba IntoMetal located at 3440 Gladstone, Lincoln, Nebraska. The employer required N-95 respirators for tasks including but not limited to cleaning out the lasers and emptying dust collection bins but had not updated the respiratory protection program to reflect this usage.
Recent events (2)
  • — I (O) $4448.6
  • — Z (S) $6844

1910.134 F02

Other-than-serious Gravity 1 1 instance 3 exposed
Issued
Aug 16, 2024
Abate by
Sep 30, 2024
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  On or about March 27, 2024, it was documented that employees engaged in laser activities in the North Building of Kinney Manufacturing, LLC, dba IntoMetal located at 3440 Gladstone, Lincoln, Nebraska.  The employer required N-95 respirators for tasks including but not limited to cleaning out the lasers and emptying dust collection bins but did not fit tested employees prior to respirator use.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2024
Abate by
Sep 30, 2024
Penalty
Initial $15,970 · Current $10,381 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about March 27, 2024, it was documented that employees engaged in laser cleaning activities in the North Building of Kinney Manufacturing, LLC dba IntoMetal located at 3440 Gladstone, Lincoln, Nebraska, were exposed to amputation hazards in that the employer did not ensure energy sources for the Bystronics lasers were isolated prior to employees inserting body part(s) while performing tasks that included but not was limited to cleaning.
Recent events (2)
  • — I (S) $10380.5
  • — Z (S) $15970

1910.134 E01

Repeat Gravity 1 1 instance 3 exposed
Issued
Aug 16, 2024
Abate by
Sep 30, 2024
Penalty
Initial $13,688 · Current $8,897 Reduced
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  On or about March 27, 2024, it was documented that employees engaged in laser activities in the south building of Kinney Manufacturing, LLC, dba IntoMetal located at 3440 Gladstone, Lincoln, Nebraska.  The employer required N-95 respirators for tasks including but not limited to cleaning out the lasers and emptying dust collection bins but did not ensure employees were medically evaluated prior to respirator usage.  Kinney Manufacturing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134(e)(1), which was contained in OSHA inspection number 1691621, citation number 2, item number 1 and was affirmed as a final order on December 5, 2023, with respect to a workplace located at 3340 North 33rd Street, Lincoln, Nebraska.
Recent events (2)
  • — I (R) $8897.2
  • — Z (R) $13688

View Kinney Manufacturing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347357543.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.