SYRACUSE, NY —
OSHA Inspection: AUTOMATED BIOMASS SYSTEMS LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AUTOMATED BIOMASS SYSTEMS LLC in 113 FALSO DRIVE, SYRACUSE, NY 13211 (NAICS 333111). OSHA activity number 347414229.
Where did this inspection happen?
- Establishment
- AUTOMATED BIOMASS SYSTEMS LLC
- Site address
- 113 FALSO DRIVE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13211
- Mailing
- 113 FALSO DRIVE, SYRACUSE, NY 13211
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333111
- Employees
- 20
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.253 B04 III
- Issued
- Penalty
- Initial $5485.00 · Current $3291.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: a) Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024; Compressed oxygen cylinders (oxidizer) and acetylene cylinders (flammable) were stored within inches of each other.
Recent events (2)
- — I (S) $3291
- — Z (S) $5485
1910.305 B02 I
- Issued
- Penalty
- Initial $4839.00 · Current $2903.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: a) Compressor Room, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, The junction box supplying power to the Qunicy Compressor did not have a cover. b) Above horizonal band saw, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, The junction box supplying power to the Hyd-Mech S-20A Series II Horizontal band saw did not have a cover.
Recent events (2)
- — I (S) $2903.4
- — Z (S) $4839
1910.305 G01 IV A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Welding Area, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, An extension cord was used in place of fixed wiring for the welding fixture used to weld cylinders. b.) Plasma Table, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, Extension cords were used in place of fixed wiring for the grinding station at the plasma table. c.) Horizonal Band Saw, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, Extension cord was used in place of fixed wiring for the grinding station at the horizonal band saw.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii):Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a.) Horizonal Band Saw, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024; A flexible cord was used to supply power from the ceiling to the Hyd-Mech S-20A Series II Horizontal band saw and no stress relief devices were present at ceiling height to prevent tension from being transmitted to joints or terminal screws.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 C10
- Issued
- Penalty
- Initial $5485.00 · Current $3291.00 Reduced
General-duty citation text
29 CFR 1910.333(c)(10):An interlock system was not returned to its operable condition when the work was completed: a) Machine Shop, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024; The interlocks on the doors to the HAAS TM-1P Serial Number 1103992 were bypassed.
Recent events (2)
- — I (S) $3291
- — Z (S) $5485
1910.1200 F06
- Issued
- Penalty
- Initial $4113.00 · Current $2468.00 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity of the hazardous chemical(s) contained therein: a.) Machine Shop, Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024; Secondary chemical containers (spray bottles) of Coolant, Isopropyl Alcohol, and Hydraulic Fluid were not labeled to identify the contents.
Recent events (2)
- — I (S) $2467.8
- — Z (S) $4113
1904.32 A04
- Issued
- Penalty
- Initial $1371.00 · Current $823.00 Reduced
General-duty citation text
29 CFR 1904.32(a)(4):The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30. a.) Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024; the employer did not post an OSHA 300A Form or equivalent for calendar year 2023.
Recent events (2)
- — I (O) $822.6
- — Z (O) $1371
1910.134 C02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(ii):The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, The employer allowed voluntary use of half face elastomeric Miller LRP-100 SN ML00894 and did not ensure the employee was medically able to use that respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E03
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check: a) Automated Biomass, 113 Falso Drive, Syracuse, NY 13211, on or about 4/16/2024, The employer did not complete annual maintenance checks on portable fire extinguishers in the workplace.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at AUTOMATED BIOMASS SYSTEMS LLC
SYRACUSE, NY—2025-11-24
AUTOMATED BIOMASS SYSTEMS, LLC
MARATHON, NY—2016-12-20 00:00:00
AUTOMATED BIOMASS SYSTEMS LLC
View AUTOMATED BIOMASS SYSTEMS LLC's full OSHA safety record →
More inspections in this industry (NAICS 333111)
EPHRATA, PA—2026-06-12
BLUE RIDGE SILO LLC
NORWOOD YOUNG AMERICA, MN—2026-06-09
111380 - PVS SACKETT-WACONIA INC
FARIBAULT, MN—2026-05-28
111336 - ENVIRONMENTAL TILLAGE SYSTEMS INC
LENNOX, SD—2026-05-07
KOYKER MANUFACTURING
NEWTON, KS—2026-05-06
MID-CONTINENT INDUSTRIES, INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347414229.