CLEVELAND, OH —
OSHA Inspection: THE ORLANDO BAKING COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of THE ORLANDO BAKING COMPANY in 7777 GRAND AVE, CLEVELAND, OH 44104 (NAICS 311999). OSHA activity number 347416729.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE ORLANDO BAKING COMPANY
- Site address
- 7777 GRAND AVE
- City
- CLEVELAND
- State
- OH
- ZIP
- 44104
- Mailing
- 7777 GRAND AVE, CLEVELAND, OH 44104
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 270
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.28 B01 I
- Issued
- Jun 27, 2024
- Abate by
- Aug 14, 2024
- Penalty
- Initial $8,619 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Unprotected sides and edges. Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: 1910.28(b)(1)(i)(A) Guardrail systems; 1910.28(b)(1)(i)(B) Safety net systems; or 1910.28(b)(1)(i)(C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems. a) On or about April 15, 2024, maintenance employees lighting the burners on the Baker Perkins direct gas fired oven (oven #8) in the Roll Line area were exposed to a fall hazard of six-foot and nine-inches (6'9"); the employer did not ensure that each employee walking and working on top of oven #8 with unprotected sides and edges that are six-foot and nine inches (6'9") above the lower level, are protected from falling by one or more of the following: 1910.28(b)(1)(i)(A) Guardrail systems; 1910.28(b)(1)(i)(B) Safety net systems; or 1910.28(b)(1)(i)(C) Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems.
Recent events (2)
- — I (S) $4000
- — Z (S) $8619
1910.263 L09 III B
- Issued
- Jun 27, 2024
- Abate by
- Oct 1, 2024
- Penalty
- Initial $16,131 · Current $14,000 Reduced
General-duty citation text
29 CFR 1910.263(l)(9)(iii)(b): Ovens with multiple burners shall be equipped with individual atmospheric pilot lights where there is sufficient secondary air in the baking chamber and where gas is available; or else each burner shall be equipped with an electric spark-type ignition device. a) On or about April 15, 2024, maintenance employees lighting the burners on the Baker Perkins direct gas fired oven (oven #8) in the Roll Line area were exposed electrical shock hazards of two times five thousand volts (2 x 5000 V) at twenty-two milliamperes (22mA); the employer did not ensure all electric spark-type ignition devices were properly maintained and kept in working order requiring employees to manually light the burners.
Recent events (2)
- — I (S) $14000
- — Z (S) $16131
1910.335 A02 I
- Issued
- Jun 27, 2024
- Abate by
- Aug 14, 2024
- Penalty
- Initial $16,131 · Current $0 Reduced
General-duty citation text
29 CFR 1910.335(a)(2)(i): When working near exposed energized conductors or circuit parts, each employee did not use insulated tools or handling equipment when the tools or handling equipment might have made contact with such conductors or parts: a) On or about April 15, 2024, maintenance employees lighting the burners on the Baker Perkins direct gas fired oven (oven #8) in the Roll Line area were exposed electrical shock hazards of two times five thousand volts (2 x 5000 V) at twenty-two milliamperes (22mA); the employer did not ensure each maintenance employee used an insulated tool and/or handling equipment (wand and torch) when the wand and torch made contact with output side of the C10-LF3 transformer.
Recent events (2)
- — I (S) $0
- — Z (S) $16131
More inspections at The Orlando Baking Company
View The Orlando Baking Company's full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347416729.