ENGLEWOOD, NJ —
OSHA Inspection: COFFIN TURBO PUMP INC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of COFFIN TURBO PUMP INC in 326 SOUTH DEAN STREET, ENGLEWOOD, NJ 07631 (NAICS 423830). OSHA activity number 347432650.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COFFIN TURBO PUMP INC
- Site address
- 326 SOUTH DEAN STREET
- City
- ENGLEWOOD
- State
- NJ
- ZIP
- 07631
- Mailing
- 326 SOUTH DEAN STREET, ENGLEWOOD, NJ 07631
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 25
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.134 C01
- Issued
- Oct 15, 2024
- Penalty
- Initial $3,042 · Current $1,521 Reduced
9020
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Test Cell Room: Employees engaged in maintenance activities, including, but not limited to, valve removal/replacement, and disassembly/removal of piping with asbestos (chrysotile) containing TSI insulation, are required to wear Honeywell and 3M half-mask dual cartridge respirators. The employer did not develop and implement a written respiratory protection program, on or about 4/23/24.
Recent events (2)
- — I (S) $1521
- — Z (S) $3042
1910.134 E01
- Issued
- Oct 15, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Test Cell Room: Employees engaged in maintenance activities including, but not limited to, valve removal/replacement, and disassembly/removal of piping with asbestos (chrysotile) containing TSI insulation, are required to wear Honeywell and 3M half-mask dual cartridge respirators. The employer did not ensure that affected employees completed a medical evaluation to determine their ability to wear respiratory protection, on or about 4/23/24.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Oct 15, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Test Cell Room: Employees engaged in maintenance activities, including, but not limited to, valve removal/replacement, and disassembly/removal of piping with asbestos (chrysotile) containing TSI insulation, are required to wear Honeywell and 3M half-mask dual cartridge respirators. The employer did not ensure that affected employees completed a fit test prior to wearing respiratory protection, on or about 4/23/24.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K03
- Issued
- Oct 15, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a) Test Cell Room: Employees engaged in maintenance related activities are required to wear Honeywell and 3M half-mask dual cartridge respirators. The employer did not ensure that affected employees completed training on the maintenance, limitation and inspection of wearing respiratory protection, on or about 4/23/24.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1001 J03 I
- Issued
- Oct 15, 2024
- Penalty
- Initial $4,056 · Current $2,028 Reduced
9020
General-duty citation text
29 CFR 1910.1001(j)(3)(i): Building and facility owner did not determine the presence, location, and quantity of ACM and/or PACM at the worksite: a) Pump Test Cell Room: Employees are required to perform steam turbo pipe testing on test cell stations. Results from an asbestos survey show that asbestos containing material (chrysotile) greater than 1 percent was detected on TSI pipe insulation located on several test cell stations, including TSI pipe insulation located in the mezzanine area. The employer did not determine the presence, location, and quantity of asbestos containing material and/or potentially asbestos containing material, on or about 4/23/24. b) Pump Test Cell Room: Employees are required to perform maintenance activities, including, but not limited to, valve repair/replacement and disassembly/assembly on TSI piping that contains asbestos insulation. Results from an asbestos survey show that asbestos containing material (chrysotile) greater than 1 percent was detected on TSI pipe insulation located on several test cell stations, including TSI pipe insulation located in the mezzanine area. The employer did not determine the presence, location, and quantity of asbestos containing material and/or potentially asbestos containing material, on or about 4/23/24.
Recent events (2)
- — I (O) $2028
- — Z (S) $4056
1910.1001 J03 III
- Issued
- Oct 15, 2024
- Abate by
- Nov 1, 2024
- Penalty
- Initial $3,042 · Current $1,521 Reduced
9020
General-duty citation text
29 CFR 1910.1001(j)(3)(iii): The employer did not inform employees, of the presence and location of ACM and/or PACM. a) Pump Test Cell Room: Asbestos containing material (chrysotile) greater than 1 percent was detected on TSI pipe insulation located on several test cell stations, including TSI pipe insulation located in the mezzanine area. Employees perform maintenance and routine steam turbo pump testing on test cell stations. The employer did not inform employees of the presence, and location of asbestos containing material, on or about 4/23/24.
Recent events (2)
- — I (S) $1521
- — Z (S) $3042
1910.1200 E01
- Issued
- Oct 15, 2024
- Penalty
- Initial $3,042 · Current $1,521 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Facility-Wide: Employees are required to work with hazardous chemicals and substances, including, but not limited to, SKL-SP Penetrant, gasket sealant, acetone, and staining fluid. The employer did not develop and implement a written hazard communication program, on or about 4/23/24.
Recent events (2)
- — I (S) $1521
- — Z (S) $3042
1910.1200 H01
- Issued
- Oct 15, 2024
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Facility-Wide: Employees are required to work with hazardous chemicals and substances, including, but not limited to, SKL-SP Penetrant, gasket sealant, acetone, and staining fluid. The employer did not provide information and training covering the safe methods to follow when working with hazardous chemicals and substances, on or about 4/23/24.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 II
- Issued
- Oct 15, 2024
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: a) Pump Test Cell Room: Employees engaged in maintenance related activities are required to work around TSI pipe insulation that contains asbestos material. The employer did not provide training on the physical and health hazards associated with asbestos, on or about 4/23/24.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1101 H02 I
- Issued
- Oct 15, 2024
- Penalty
- Initial $3,042 · Current $1,521 Reduced
9020
General-duty citation text
29 CFR 1926.1101(h)(2)(i): The employer failed to implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) [except (d)(1)(iii)], and (f) through (m), which covers each employee required by 29 CFR 1926.1101 to use a respirator: a) Test Cell Room: Employees engaged in Class III repair work of asbestos containing TSI pipe insulation were required to wear Honeywell and 3M half-mask dual cartridge respirators. The employer did not develop and implement a written respiratory protection program, on or about 4/23/24.
Recent events (2)
- — I (S) $1521
- — Z (S) $3042
1926.1101 K09 I
- Issued
- Oct 15, 2024
- Penalty
- Initial $4,056 · Current $2,028 Reduced
9020
General-duty citation text
29 CFR 1926.1101(k)(9)(i): The employer did not institute, at no cost to employees, a training program for each employee who was likely to be exposed in excess of the permissible exposure limit (PEL) and for each employee who performed Class I through IV asbestos operations: a) Test Cell Room (Test Station Cell #1): Employees engaged in Class III repair work of asbestos containing TSI pipe insulation did not complete training prior to conducting repair work (encapsulation). The employer did not develop and implement a training program for employees engaged in Class III repair work on asbestos containing pipe insulation, on or about 4/23/24.
Recent events (2)
- — I (S) $2028
- — Z (S) $4056
1910.1001 J04 IV
- Issued
- Oct 15, 2024
- Abate by
- Nov 1, 2024
- Penalty
- Initial $0 · Current $0
9020
General-duty citation text
29 CFR 1910.1001(j)(4)(iv): Signs identifying the presence, location and work practices to not disturb the ACM and/or PACM contained within the area were not posted at the entrance where employees were reasonably expected to enter: a) Pump Test Cell Room: Employees engaged in steam turbo pump testing and maintenance related work were required to near asbestos containing TSI pipe insulation. Asbestos containing material (chrysotile) greater than 1 percent was detected on TSI pipe insulation located on several test cell stations, as well as TSI pipe insulation located in the mezzanine area. The employer did not post signs at the entrance of the test cell room, identifying the presence, location and work practices to prevent disturbance of asbestos containing TSI pipe insulation, on or about 4/23/24.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.41 A01 I
- Issued
- Aug 27, 2024
- Penalty
- Initial $1,014 · Current $761 Reduced
General-duty citation text
29 CFR 1904.41(a)(1)(i):The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date: a) Facility-wide: On or about, 4/23/24, the employer failed during calendar year 2023, to electronically submit information from their OSHA Form 300A or equivalent by 3/02/2024.
Recent events (2)
- — I (O) $760.5
- — Z (O) $1014
More inspections at Coffin Turbo Pump INC
View Coffin Turbo Pump INC's full OSHA safety record →
More inspections in this industry (NAICS 423830)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347432650.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.