Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELECTRIC SOLUTIONS INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ELECTRIC SOLUTIONS INC. in 5189 CLARK STATE RD, GAHANNA, OH 43230 (NAICS 238210). OSHA activity number 347497281.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Electric Solutions INC. — free Get an email when a new federal OSHA severe-injury report for Electric Solutions INC. is published. One employer, no account, unsubscribe in one click.
Site address
5189 CLARK STATE RD
City
GAHANNA
State
OH
ZIP
43230
Mailing
1625 EASTGATE PARKWAY, GAHANNA, OH 43230
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238210
Employees
30
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2024
Penalty
Initial $9,680 · Current $9,680
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, a baker supported scaffold was in use onsite that was not fully planked or decked between the front uprights. There were bowed wooden 2" x 6" x 8' boards in use stretched across part of the scaffold, and onto the exterior of excavation with a piece of plywood in use on top of it. Employees were thereby exposed from falls to lower level ranging from approximately 2-5 feet from the platform of the scaffold while performing electrical installation work.
Recent events (2)
  • — C (S) $9680
  • — Z (S) $9680

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.   a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, a baker supported scaffold was in use onsite that was not supported by base plates, mud sills, or other adequate foundation. The scaffold was installed inside of an excavation with observed settling. As a result, employees were exposed to fall hazards when working from the baker supported scaffold to perform electrical installation work.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1926.451 C02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2024
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(iii): Unstable objects shall not be used as working platforms.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, a baker supported scaffold was in use onsite that had unstable wooden boards in use as working platforms in that two wooden 2" x 6" x 8' planks were in use at an angle across the top of the baker support scaffold as well as a piece of plywood. The wooden boards were heavily bowed and unstable in the manner in which they were installed. As a result, employees were exposed to fall hazards ranging from approximately 2-5 feet from the scaffold while performing electrical installation work.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1926.451 F03

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 5, 2024
Abate by
Sep 17, 2024
Penalty
Initial $9,680 · Current $9,680
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  a. Located at the job site at 5189 Clark State Rd, Gahanna, Ohio: On or about May 21, 2024, and at times prior, a baker supported scaffold was in use onsite that was not visibly inspected by a competent person before each work shift. The scaffold was in unsafe condition in that the footing and uprights were not on base plates, mud sills, or adequate firm foundation; it was not fully planked; and unstable objects were used as the working platform. As a result, employees were exposed to fall hazards when working from the baker supported scaffold to perform electrical installation work.
Recent events (2)
  • — C (S) $9680
  • — Z (S) $9680

View Electric Solutions INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347497281.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.