OSHA Inspection: PAPPAS COMPANY, LTD.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PAPPAS COMPANY, LTD. in 464 ELM STREET, DEERFIELD, IL 60015 (NAICS 237110). OSHA activity number 347784191.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pappas Company, LTD. — free Get an email when a new federal OSHA severe-injury report for Pappas Company, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
464 ELM STREET
City
DEERFIELD
State
IL
ZIP
60015
Mailing
2100 JOHNS CT., GLENVIEW, IL 60025
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
237110
Employees
45
Ownership type
A

8 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 6, 2025
Penalty
Initial $10,924 · Current $6,500 Reduced
29 CFR  1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  a) On or about September 30, 2024, the employer did not ensure that all hand tools, including the Hercules 4 ?" Heavy Duty Angle Grinder, Model HE61S, were equipped with guards when in use.  The Hercules Angle Grinder was designed to accommodate a guard, and one was not used when it was utilized to cut the sanitary line.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $6500
  • — Z (S) $10924

1926.405 A02 II I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2025
Penalty
Initial $7,282 · Current $5,000 Reduced
29 CFR  1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  a) On or about September 30, 2024, the employer did not ensure that all flexible cords used for temporary wiring, including the extension cord suppling power to the Hercules 4 ?" Heavy Duty Angle Grinder, Model HE61S, were protected from damage.  The extension cord was run over an active roadway that was traveled by large commercial vehicles and showed signs of damage.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $7282

1926.651 H01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2025
Abate by
Apr 1, 2025
Penalty
Initial $7,282 · Current $2,500 Reduced
29 CFR  1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation.   a) On September 30, 2024, employees working an excavation measuring approximately nine (9) feet deep were not protected from the hazards related to water accumulation.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $2500
  • — Z (S) $7282

1926.652 D01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2025
Abate by
Apr 1, 2025
Penalty
Initial $7,282 · Current $0 Reduced
29 CFR  1926.652(d)(1): Materials and equipment used for protective systems were not free from damage or defects that might impair their proper function:   a) On September 30, 2024, at the above addressed jobsite, the employer did not ensure that support members, such as the vertical fin board used in the excavation, were free from recognized hazards including cracks, bowing and missing corners.   These defects could impair the proper function and structural integrity of the board.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7282

1926.1053 B01

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2025
Penalty
Initial $7,282 · Current $2,500 Reduced
29 CFR  1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  a) On September 30, 2024, the portable metal ladder used by employees to access and egress the trench, measuring approximately nine (9) feet in depth, did not extend at least three (3) feet above the upper landing surface.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $2500
  • — Z (S) $7282

1926.652 A01

Repeat Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2025
Penalty
Initial $63,718 · Current $31,000 Reduced
29 CFR  1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a) On September 30, 2024, at the above addressed jobsite, employees were exposed to cave-in hazards while installing cave-in protection in an unprotected excavation of up to nine (9) feet deep.  The employer did not ensure that employees were protected from cave-in hazards while in the excavation.  Pappas Company, LTD. was previously cited for a violation of this occupational safety and health standard 29CFR 1926.652(a)(1), which was contained in OSHA inspection number 1587694, citation number 1, item number 1 and was affirmed as a final order on September 28, 2022, with respect to a workplace located at 2120 St. Johns Avenue in Highland Park, Illinois.  Pappas Company, LTD. was previously cited for a violation of this occupational safety and health standard 29CFR 1926.652(a)(1), which was contained in OSHA inspection number 1710461, citation number 2, item number 1 and was affirmed as a final order on April 29, 2024, with respect to a workplace located at 205 Chestnut Street in Winnetka, Illinois.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (R) $31000
  • — Z (R) $63718

1926.652 C02 I

Repeat Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2025
Penalty
Initial $25,487 · Current $0 Reduced
29 CFR  1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer:  a) On September 30, 2024, at the above addressed jobsite, employees in excavations were not provided with adequate cave-in protection as the protective system that was being utilized was not in accordance with all specifications.  The shoring was installed horizontally, the number of shores were inadequate, and the number of boards were not adequate for the size of the excavation.   Pappas Company, LTD. was previously cited for a violation of this occupational safety and health standard 29CFR 1926.652(c)(2)(i), which was contained in OSHA inspection number 1710461, citation number 1, item number 2 and was affirmed as a final order on April 29, 2024, with respect to a workplace located at 205 Chestnut Street in Winnetka, Illinois.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (R) $0
  • — Z (R) $25487

1926.652 C03 III

Repeat 1 instance 2 exposed
Issued
Mar 6, 2025
Abate by
Apr 1, 2025
Penalty
Initial $3,641 · Current $2,500 Reduced
29 CFR  1926.652(c)(3)(iii): At least one copy of the tabulated data, which identifies the registered professional engineer who approved the data, was not maintained at the jobsite during construction of the protective system:  a) On September 30, 2024, at the above addressed jobsite, the employer did not maintain a copy of the tabulated data for the hydraulic shoring used at the site.  Pappas Company, LTD. was previously cited for a violation of this occupational safety and health standard 1926.652(c)(3)(iii), which was contained in OSHA inspection number 1710461, citation number 3, item number 1 and was affirmed as a final order on April 29, 2024, with respect to a workplace located at 205 Chestnut Street in Winnetka, Illinois.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (R) $2500
  • — Z (R) $3641

View Pappas Company, LTD.'s full OSHA safety record →