MONGMONG, GU —
OSHA Inspection: SMITHBRIDGE GUAM, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SMITHBRIDGE GUAM, INC. in AYUYU PROPERTY M16 L2066-REM-4NEW, 204A PUNZALAN ST., MONGMONG, GU 96910 (NAICS 236115). OSHA activity number 347826943.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SMITHBRIDGE GUAM, INC.
- Site address
- AYUYU PROPERTY M16 L2066-REM-4NEW, 204A PUNZALAN ST.
- City
- MONGMONG
- State
- GU
- ZIP
- 96910
- Mailing
- P.O. BOX 11700, YIGO, GU 96929
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 349
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.303 B01
- Issued
- Feb 18, 2025
- Penalty
- Initial $7,093 · Current $4,965 Reduced
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section. First floor: The grinder used to cut a marble countertop was missing a guard exposing employees to struck by hazards.
Recent events (2)
- — I (S) $4965.1
- — Z (S) $7093
1926.405 B02
- Issued
- Feb 18, 2025
- Penalty
- Initial $7,093 · Current $4,965 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: First floor: Live outlets used to power tools and equipment for work were missing cover exposing employees to electrical and fire hazards.
Recent events (2)
- — I (S) $4965.1
- — Z (S) $7093
1926.405 J01 I
- Issued
- Feb 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact: First floor: Live wiring from receptacles were protruding out into the room where employees were laying tiles exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Feb 18, 2025
- Penalty
- Initial $9,457 · Current $6,620 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Second floor: Employees working on the second floor without fall protection were exposed to a fall up to 12 feet.
Recent events (2)
- — I (S) $6619.9
- — Z (S) $9457
1926.95 A
- Issued
- Feb 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.95(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, were not provided: Second floor: Employes not wearing gloves when using thin set mortar to install tiling were exposed to skin irritation and dermatitis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.102 A01
- Issued
- Feb 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: Second floor: An employee was not wearing eye protection when using a drill to mix the thin set mortar. The employee was exposed to eye injury.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 G02 IV
- Issued
- Feb 18, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: First floor: The outer insulation to the power cable for the blower used for ventilation was pulled from the plug exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Smithbridge Guam, INC.
View Smithbridge Guam, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347826943.