OSHA Inspection: PFM/VERTEX JV

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PFM/VERTEX JV in BUILDING B GUAM COMMUNITY COLLEGE, MANGILAO, GU 96913 (NAICS 236220). OSHA activity number 347843278.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pfm/Vertex JV — free Get an email when a new federal OSHA severe-injury report for Pfm/Vertex JV is published. One employer, no account, unsubscribe in one click.
Establishment
PFM/VERTEX JV
Site address
BUILDING B GUAM COMMUNITY COLLEGE
City
MANGILAO
State
GU
ZIP
96913
Mailing
202 HILTON ROAD UNIT 7, TAMUNING, GU 96913
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
56
Ownership type
A

6 citations on file for this inspection.

1910.134 E01

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Jan 14, 2025
Penalty
Initial $4,839 · Current $0 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103)  The employer did not provide a medical evaluation to employees who were required to wear N95 respirators during cutting and chipping operations. Employees were exposed to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4839

1910.134 F02

Other-than-serious Gravity 1 1 instance 4 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103)  Employees required to wear N95 respirators were not fit tested prior to use. Employees were exposed to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 G01 I B

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(B): Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function:  In front of the building: An employee was wearing an N95 respirator over a head sock while chipping and cutting cement.  The employee was exposed to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.405 A02 II J

Serious Gravity 1 1 instance 6 exposed
Issued
Jan 14, 2025
Penalty
Initial $4,839 · Current $3,387 Reduced
29 CFR 1926.405(a)(2)(ii)(J): Flexible cords used with temporary and portable lights were not designed for hard or extra-hard usage:   Room first floor: Single wires used for temporary lighting exposed employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $3387.3
  • — Z (S) $4839

1926.405 A02 II E

Other-than-serious 1 instance 6 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage.  First floor: Low hanging lights for temporary lighting were not protected from breakage exposing employees to laceration and electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.405 G02 IV

Other-than-serious 1 instance 6 exposed
Issued
Jan 14, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  First floor: The outer insulation to the power cord for the fan used for ventilation was pulled from the fan exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0