Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: I.K. STOLTZFUS SERVICE CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of I.K. STOLTZFUS SERVICE CORP. in 601 ROBERT FULTON HIGHWAY, QUARRYVILLE, PA 17566 (NAICS 238320). OSHA activity number 347878308.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch I.K. Stoltzfus Service Corp. — free Get an email when a new federal OSHA severe-injury report for I.K. Stoltzfus Service Corp. is published. One employer, no account, unsubscribe in one click.
Site address
601 ROBERT FULTON HIGHWAY
City
QUARRYVILLE
State
PA
ZIP
17566
Mailing
1896 AUCTION ROAD, MANHEIM, PA 17545
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

8 citations on file for this inspection.

1926.451 G03 IV

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
May 8, 2025
Abate by
Oct 1, 2025
Penalty
Initial $4,729 · Current $4,000 Reduced
29 CFR  1926.451(g)(3)(iv): Vertical lifelines and suspension ropes were attached to or used the same point of anchorage:   (a) Quarryville Water Tank, Interior - Employees worked from two separate swing stage scaffolds in the interior of the over 100-foot high cylindrical water tank to perform tasks such as welding, abrasive blasting, and painting.  The employees attached the scaffolds' suspension ropes to the same anchorage used for vertical lifelines for personal fall arrest systems, on or about November 13, 2024.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $4729

1926.502 D15

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
May 8, 2025
Abate by
Jun 4, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not  independent of any anchorage point being used to support or suspend platforms:  (a) Quarryville Water Tank, Interior - Employees worked from two separate swing stage scaffolds in the interior of the over 100-foot high cylindrical water tank to perform tasks such as welding, abrasive blasting, and painting.  The employees attached vertical lifelines for personal fall arrest systems to the same anchorage used to support the scaffolds' suspension ropes, on or about November 13, 2024.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1204 E01 II

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
May 8, 2025
Abate by
Oct 1, 2025
Penalty
Initial $4,729 · Current $4,000 Reduced
29 CFR 1926.1204(e)(1)(ii): When entry was authorized, continuous monitoring of entry conditions in the areas where authorized entrants were working did not occur nor did periodic monitoring occur, in accordance with paragraph (e)(2) of this section for monitoring an atmospheric hazard, when a demonstration could be made that equipment for continuously monitoring that hazard was not commercially available:  (a) Quarryville Water Tank, Interior - The employer authorized employees to enter the interior of the water tank to perform tasks such as welding, abrasive blasting and painting.  During entry, no continuous or periodic atmospheric monitoring occurred in the areas where the employees worked, including at grade level and at various levels above grade while employees worked from swing stage scaffolding inside the over 100-foot high water tank, on or about November 13, 2024.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $4729

1926.1204 E02

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
May 8, 2025
Abate by
Jun 4, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.1204(e)(2): The employer did not continuously monitor atmospheric hazards unless the employer demonstrated that the equipment for continuously monitoring a hazard was not commercially available or that periodic monitoring was of sufficient frequency to ensure that the atmospheric hazard was being controlled at safe levels.  If continuous monitoring is not used, periodic monitoring is required with sufficient frequency to ensure that acceptable entry conditions are being maintained during the course of entry operations:   (a) Quarryville Water Tank, Interior - The employer authorized employees to enter the interior of the water tank to perform tasks such as abrasive blasting and painting.  During entry, no continuous or periodic atmospheric monitoring occurred, on or about November 13, 2024.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1206 E

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
May 8, 2025
Abate by
Oct 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.1206(e): The entry permit that authorized entry to a permit space did not identify the means of detecting an increase in atmospheric hazard levels in the event the ventilation system stops working:   (a) Quarryville Water Tank, Interior - The employer authorized employees to enter the interior of the water tank to perform tasks such as welding, abrasive blasting and painting.  The entry permit that authorized entry did not identify the means of detecting an increase in atmospheric hazard levels in the event the ventilation system stopped working, on or about November 13, 2024.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1206 F

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
May 8, 2025
Abate by
Jun 4, 2025
Penalty
Initial $0 · Current $0
29 CFR 926.1206(f): The entry permit that authorized entry to a permit space did not identify each person, by name, currently serving as an attendant:   (a) Quarryville Water Tank, Interior - The employer authorized employees to enter the interior of the water tank to perform tasks such as welding, abrasive blasting and painting.  The entry permit that authorized entry did not identify by name, the person currently serving as the attendant in that the entry permits dated November 13, 15, and 18, 2024 listed the same names for attendants and entrants without distinguishing who served as the attendant and when.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1206 G

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
May 8, 2025
Abate by
Jun 4, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.1206(g): The entry permit that authorized entry to a permit space did not identify the individual, by name, currently serving as entry supervisor, and the signature or initials of each entry supervisor who authorizes entry:  (a) Quarryville Water Tank, Interior - The employer authorized employees to enter the interior of the water tank to paint, and the entry permits dated November 13 and 18, 2024 that authorized entry did not identify by name, the person serving as the entry supervisor.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1206 K

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
May 8, 2025
Abate by
Jun 4, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.1206(k): The entry permit that authorized entry to a permit space did not identify the results of tests and monitoring performed under �1926.1204(e), accompanied by the names or initials of the testers and by an indication of when the tests were performed:  (a) Quarryville Water Tank, Interior - The employer authorized employees to enter the interior of the water tank to paint, and the entry permits dated November 13 and 18, 2024 that authorized entry did not have the names or initials of the person who performed the pre-entry atmospheric monitoring.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0