OSHA Inspection: QSI, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of QSI, LLC in 2860 W MAIN STREET, GALESBURG, IL 61401 (NAICS 561720). OSHA activity number 347981110.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch QSI, LLC — free Get an email when a new federal OSHA severe-injury report for QSI, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
QSI, LLC
Site address
2860 W MAIN STREET
City
GALESBURG
State
IL
ZIP
61401
Mailing
412 GEORGIA AVENUE SUITE 300, CHATTANOOGA, TN 37403
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
5
Ownership type
A

2 citations on file for this inspection.

1910.146 C02

Other-than-serious Gravity 1 4 instances 1 exposed
Issued
May 6, 2025
Abate by
Jun 5, 2025
Penalty
Initial $6,632 · Current $0 Reduced
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:    On or about January 15, 2025, employees were performing cleaning activities on the:  a.  Nowicki 650-E Mixer, Serial Number 2407, located in the Grinding Room and the employer did not inform exposed employees of the existence and location of, and danger posed by such permit-required confined spaces through the posting of danger signs or other equally effective means.  b. Thompson 5000 Grinder adjacent to the Nowicki 650-E Mixer located in the Grinding Room and the employer did not inform exposed employees of the existence and location of, and danger posed by such permit-required confined spaces through the posting danger signs or other equally effective means.    c. Thompson 5000 Grinder located on the opposite wall from the Nowicki 650-E Mixer located in the Grinding Room and the employer did not inform exposed employees of the existence and location of, and danger posed by such permit-required confined spaces through the posting of danger signs or other equally effective means. A sign reading DANGER - PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or other similar language was not used.  d. Nowicki 650-E Mixer located in the Processing Room and the employer did not inform exposed employees of the existence and location of, and danger posed by such permit-required confined spaces through the posting of danger signs or other equally effective means.  A sign reading DANGER - PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or other similar language was not used.
Recent events (2)
  • — I (O) $0
  • — Z (S) $6632

1910.147 C04 II

Other-than-serious 38 instances 5 exposed
Issued
May 6, 2025
Abate by
Jun 5, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about January 15, 2025, employees were required to perform cleaning activities on equipment and the energy control procedures for the:    a. BAS 02SA 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  b. BAS 02SA 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  c. BAS 02SA 3 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  d. Bowl Mixer 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  e. Bowl Mixer 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  f. Bowl Mixer 3 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  g. Dumper 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  h. Dumper 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  i. Handtmann PVLH 24 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  j. Incline Conveyor 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  k. Incline Conveyor 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  l. Mixer 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  m. Mixer 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  n. Multi Vac Compressor did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  o. Nock did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  p. Packaging Metal Detector 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  q. Packaging Metal Detector 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  r. Packaging Metal Detector 3 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  s. Packaging Metal Detector 4 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  t. Packaging Metal Detector 5 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  u. Packaging Metal Detector 6 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  v. Package Line 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  w. Package Line 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  x. Package Line 3 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  y. Package Line 4 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  z. Package Line 5 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  aa. Package Line 6 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  bb. Roll Cutter did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  cc. Roll Stock Cutter 1 did not specify how to disconnect the pneumatic energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  dd. Roll Stock Cutter 2 did not specify how to disconnect the pneumatic energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  ee. Roll Stock Cutter 3 did not specify how to disconnect the pneumatic energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  ff. Shacker 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  gg. Shacker 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  hh. Sheeter 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  ii. Sheeter 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  jj. Stuffer 1 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  kk. Stuffer 2 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.  ll. Stuffer 3 did not specify how to disconnect the 480V electrical energy source, specify where to place lockout device, and did not specify how to release the stored or residual energy in the equipment.