On , OSHA opened a planned safety inspection of CONCEPTS IN MILLWORK, INC. in 1490 TUSKEGEE PLACE, COLORADO SPRINGS, CO 80915 (NAICS 337110). OSHA activity number 347992935.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Concepts in Millwork, INC. — free Get an email when a new federal OSHA severe-injury report for Concepts in Millwork, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1490 TUSKEGEE PLACE
City
COLORADO SPRINGS
State
CO
ZIP
80915
Mailing
1490 TUSKEGEE PLACE, COLORADO SPRINGS, CO 80915
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
50
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $8,276 · Current $6,000 Reduced
29 CFR  1910.147(c)(4)(ii):Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  a) On or about March 28, 2025, and at times prior the employer did not ensure that the equipment specific procedures for lockout tagout clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy and the means to enforce compliance in that the procedures did not include scope, purpose, authorization, and did not outline the control and release of stored energy including but not limited to electrical charge at input terminals,  and thermal energy.
Recent events (2)
  • — I (O) $6000
  • — Z (S) $8276

1910.147 C06 I

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed.  a) On or about March 28, 2025, and at times prior, the employer did not conduct a periodic inspection of the energy control procedures at least annually to ensure that the procedures and the requirement of this standard were being followed.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.147 C07 I A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On or about March 28, 2025, and at times prior, the employer did not ensure that authorized employee performing maintenance on equipment received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and mean neccessary for energy isolation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D06

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(6):Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished.  a) On or about March 28, 2025, and at times prior the employer did not ensure that prior to starting work on machines or equipment that had been locked out, that the authorized employee verified the isolation and deenergization of the machine or equipment had been accomplished.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F03 II

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.147(f)(3)(ii):Group lockout or tagout devices were not used in accordance with procedures required by 29 CFR 1910.147(c)(4).  a) On or about March 28, 2025, and at times prior the employer did not ensure that group lockout or tagout devices were used in accordance with procedures required by 29 CFR 1910.147
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 C02 I

Other-than-serious 1 instance 25 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.134(c)(2)(i):Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible.  On or about March 28, 2025, and at times prior the employer did not ensure that voluntary respirator users were provided with the information contained in Appendix D to 29 CFR 1910.134, when voluntary use of N95 disposable masks was permissible by the employer.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 1 instance 50 exposed
Issued
Aug 6, 2025
Abate by
Sep 11, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes.   a) On or about March 28, 2025, and at times prior the employer did not ensure that compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. when used for cleaning to prevent scratches while drilling for hinges was reduced to less than 30 psi.  b) On or about March 28, 2025, and at times prior, the employer did not ensure that compressed air was not used by employees to clean saw dust of themselves or their clothing.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Concepts in Millwork, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347992935.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.