MECHANICSBURG, PA —
OSHA Inspection: DARAN GENERAL CARPENTRY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DARAN GENERAL CARPENTRY, LLC in VICTORY CIRCLE LOT 8, MECHANICSBURG, PA 17050 (NAICS 238130). OSHA activity number 348015967.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DARAN GENERAL CARPENTRY, LLC
- Site address
- VICTORY CIRCLE LOT 8
- City
- MECHANICSBURG
- State
- PA
- ZIP
- 17050
- Mailing
- 4619 GARRETT AVENUE, BELTSVILLE, MD 20705
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- May 28, 2025
- Abate by
- Jun 24, 2025
- Penalty
- Initial $11,585 · Current $11,585
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) Victory Court, Lot 8, Mechanicsburg, PA - On or about January 31, 2025, employees were sheathing the second-story floor of a single-family dwelling at a height greater than 6 feet above grade level without utilizing acceptable means or methods of fall protection. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- — Z (S) $11585
1926.503 A01
- Issued
- May 28, 2025
- Abate by
- Jun 24, 2025
- Penalty
- Initial $9,931 · Current $9,931
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Victory Court, Lot 8, Mechanicsburg, PA - On or about January 31, 2025, employees were sheathing the second-story floor of a single-family dwelling at a height greater than 6 feet above grade level without acceptable means or methods of fall protection, and did not have fall protection training. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $9931
1926.50 B
- Issued
- May 28, 2025
- Abate by
- Jun 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.50(b): Provisions were not made prior to commencement of the project for prompt medical attention in case of serious injury. a) Victory Court, Lot 8, Mechanicsburg, PA - On or about January 31, 2025, employees who were sheathing the floor of a second story, single-family residence had not identified or made provisions for medical care in-case of serious injury. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (O) $0
More inspections at Daran General Carpentry, LLC
View Daran General Carpentry, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348015967.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.