KETCHIKAN, AK ·
OSHA Inspection: VIGOR INDUSTRIAL LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of VIGOR INDUSTRIAL LLC in 3801 TONGASS AVE., KETCHIKAN, AK 99901 (NAICS 336611). OSHA activity number 348032889.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIGOR INDUSTRIAL LLC
- Site address
- 3801 TONGASS AVE.
- City
- KETCHIKAN
- State
- AK
- ZIP
- 99901
- Mailing
- 5555 N CHANNEL AVE, PORTLAND, OR 97217
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 74
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.212 A03 II
- Issued
- Feb 27, 2025
- Penalty
- Initial $12,059 · Current $10,853 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Machine shop - On or about February 10, 2025 and at times prior thereto, employees performing metal cutting activities using the DoALL Power saw, model number C-70, Serial Number 156-671997, were exposed to amputation and laceration hazards in that the band saw was missing a guard next to the point of operation. OSHA Instruction: Shipyard Employment "Tool Bag" Directive - CPL 02-00-162 allows for the applicability of 29 CFR 1910.212.(a)(3)(ii) in the ship building and ship repair industry.
Recent events (2)
- · I (S) $10853.1
- · Z (S) $12059
1910.305 B01 II
- Issued
- Feb 27, 2025
- Penalty
- Initial $10,050 · Current $9,045 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. (a) Tool Shop Third Floor - On or about February 10, 2025 and at times prior thereto, the employees were exposed to electrical hazards that would result in cardiac arrest, severe burns and even death from contact with live electrical conductors rated at 60 AMP and 600 Volts Alternating Current (VAC) through the unused openings on General Electric (GE) Heavy Duty Safety Switch. OSHA Instruction: Shipyard Employment "Tool Bag" Directive - CPL 02-00-162 allows for the applicability of 29 CFR 1910.305(b)(1)(ii) in the ship building and ship repair industry.
Recent events (2)
- · I (S) $9045
- · Z (S) $10050
1915.56 B02
- Issued
- Feb 27, 2025
- Penalty
- Initial $8,038 · Current $7,234 Reduced
General-duty citation text
29 CFR 1915.56(b)(2):Welding cable was not free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected. M/V Laconte - Starboard Fuel Oil Settling Tank- On or about February 10, 2025 and at times prior thereto, employees performing welding activities were exposed to electrical shock in that they were welding using welding cables that had been damaged and then repaired with electrical tape, approximately 32 inches from the lead.
Recent events (2)
- · I (S) $7234.2
- · Z (S) $8038
1915.73 C
- Issued
- Feb 27, 2025
- Penalty
- Initial $10,050 · Current $9,045 Reduced
General-duty citation text
29 CFR 1915.73(c):When employees are working around open hatches not protected by coamings to a height of 24 inches or around other large openings, the edge of the opening shall be guarded in the working area to height of 36 to 42 inches, except where the use of such guards is made impracticable by the work actually in progress. M/V Laconte - Car Deck - On or about February 10, 2025 and at times prior thereto, employees performing ship repair activities were exposed to fall hazards in that they were working near an open hatch with a coaming height of 10 inches that was not guarded to prevent falls.
Recent events (2)
- · I (S) $9045
- · Z (S) $10050
More inspections at Vigor Industrial LLC