Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: VIGOR INDUSTRIAL LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VIGOR INDUSTRIAL LLC in 3801 TONGASS AVE., KETCHIKAN, AK 99901 (NAICS 336611). OSHA activity number 348032889.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vigor Industrial LLC for free Get an email when a new federal OSHA severe-injury report for Vigor Industrial LLC is published. One employer, no account, unsubscribe in one click.
Site address
3801 TONGASS AVE.
City
KETCHIKAN
State
AK
ZIP
99901
Mailing
5555 N CHANNEL AVE, PORTLAND, OR 97217
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
74
Ownership type
Private (A)

4 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2025
Penalty
Initial $12,059 · Current $10,853 Reduced
29 CFR  1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Machine shop - On or about February 10, 2025 and at times prior thereto, employees performing metal cutting activities using the DoALL Power saw, model number C-70, Serial Number 156-671997, were exposed to amputation and laceration hazards in that the band saw was missing a guard next to the point of operation.  OSHA Instruction: Shipyard Employment "Tool Bag" Directive - CPL 02-00-162 allows for the applicability of 29 CFR 1910.212.(a)(3)(ii) in the ship building and ship repair industry.
Recent events (2)
  • · I (S) $10853.1
  • · Z (S) $12059

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2025
Penalty
Initial $10,050 · Current $9,045 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  (a)  Tool Shop Third Floor - On or about February 10, 2025 and at times prior thereto, the employees were exposed to electrical hazards that would result in cardiac arrest, severe burns and even death from contact with live electrical conductors  rated at 60 AMP and 600 Volts Alternating Current (VAC) through the unused openings on General Electric (GE) Heavy Duty Safety Switch.  OSHA Instruction: Shipyard Employment "Tool Bag" Directive - CPL 02-00-162 allows for the applicability of 29 CFR 1910.305(b)(1)(ii) in the ship building and ship repair industry.
Recent events (2)
  • · I (S) $9045
  • · Z (S) $10050

1915.56 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2025
Penalty
Initial $8,038 · Current $7,234 Reduced
29 CFR  1915.56(b)(2):Welding cable was not free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected.  M/V Laconte - Starboard Fuel Oil Settling Tank- On or about February 10, 2025 and at times prior thereto, employees performing welding activities were exposed to electrical shock in that they were welding using welding cables that had been damaged and then repaired with electrical tape, approximately 32 inches from the lead.
Recent events (2)
  • · I (S) $7234.2
  • · Z (S) $8038

1915.73 C

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 27, 2025
Penalty
Initial $10,050 · Current $9,045 Reduced
29 CFR  1915.73(c):When employees are working around open hatches not protected by coamings to a height of 24 inches or around other large openings, the edge of the opening shall be guarded in the working area to height of 36 to 42 inches, except where the use of such guards is made impracticable by the work actually in progress.  M/V Laconte - Car Deck - On or about February 10, 2025 and at times prior thereto, employees performing ship repair activities were exposed to fall hazards in that they were working near an open hatch with a coaming height of 10 inches that was not guarded to prevent falls.
Recent events (2)
  • · I (S) $9045
  • · Z (S) $10050

View Vigor Industrial LLC's full OSHA safety record →