Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERNATIONAL CUSHIONING COMPANY, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of INTERNATIONAL CUSHIONING COMPANY, LLC in 2101 CEDAR STREET, FREMONT, OH 43420 (NAICS 326140). OSHA activity number 348079245.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch International Cushioning Company, LLC — free Get an email when a new federal OSHA severe-injury report for International Cushioning Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2101 CEDAR STREET
City
FREMONT
State
OH
ZIP
43420
Mailing
240 BOUNDARY ROAD ATTN: BUDDY BUSSEY, MARLBORO, NJ 07746
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
20
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 4 exposed
Issued
Jul 23, 2025
Abate by
Sep 3, 2025
Penalty
Initial $13,902 · Current $7,500 Reduced

Hazardous substances K105

OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards associated with the accumulation of flammable isobutane gas.  International Cushioning Company, LLC located at 2101 Cedar Street in Fremont, Ohio;  On or about February 25, 2025, the employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees recycling scrap foam in the re-grinders on the recycling line were exposed to fire and explosion hazards associated with the accumulation of flammable isobutane gas  above the lower explosive limit.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $13902

1910.132 A

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 23, 2025
Abate by
Sep 3, 2025
Penalty
Initial $13,902 · Current $7,500 Reduced
29 CFR  1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  International Cushioning Company, LLC located at 2101 Cedar Street in Fremont, Ohio;  On or about February 25, 2025, the employer did not ensure employees who were required to load the polystyrene foam into re-grinders were provided with flame retardant clothing. Employees feeding scrap foam sheets into the re-grinders (red and green) were exposed to fire and explosion hazards when levels of isobutane exceed the lower explosion limit.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $13902

1910.305 G01 IV A

Other-than-serious Gravity 5 2 instances 4 exposed
Issued
Jul 23, 2025
Abate by
Sep 3, 2025
Penalty
Initial $7,944 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  International Cushioning Company, LLC located at 2101 Cedar Street in Fremont, Ohio;  Instance A On or about February 25, 2025, the employer did not ensure that flexible cables were not used as a substitute for fixed wiring. Employees were exposed to electrical shock and fire hazards in that a flexible extension cord was used as fixed wiring to power electrical equipment such as, but not limited to, the Takk Static Elimination Blower.  Instance B   On or about February 25, 2025, the employer did not ensure that flexible cables were not used as a substitute for fixed wiring. Employees were exposed to electrical shock and fire hazards in that a flexible extension cord was used as fixed wiring to power electrical equipment such as, but not limited to, an overhead light on the recycling line above the hopper and conveyor.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7944

View International Cushioning Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348079245.