Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DEPARTMENT OF INTERIOR - BUREAU OF LAND MANAGEMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEPARTMENT OF INTERIOR - BUREAU OF LAND MANAGEMENT in 3900 EAST IDAHO STREET, ELKO, NV 89801 (NAICS 924120). OSHA activity number 348101098.

Watch Department OF Interior - Bureau OF Land Management — free Get an email when a new federal OSHA severe-injury report for Department OF Interior - Bureau OF Land Management is published. One employer, no account, unsubscribe in one click.
Site address
3900 EAST IDAHO STREET
City
ELKO
State
NV
ZIP
89801
Mailing
3900 EAST IDAHO STREET, ELKO, NV 89801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
100
Ownership type
D

3 citations on file for this inspection.

1910.215 B09

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 16, 2025
Abate by
May 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  Work Shop: The left side adjustment between the tongue and the abrasive wheel of a DeWalt DW758 8" bench grinder exceeded one fourth inch. There was a measured gap of 1.125 inches. This condition potentially exposed employees to caught-in hazards.
Recent events (1)
  • — Z (S) $0

1910.243 C03

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 16, 2025
Abate by
May 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.243(c)(3): Abrasive wheels used on right angle head grinders were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:  Tool Shop: Two DeWalt angle grinders were not equipped with safety guards having a maximum exposure angle of 180 degrees. Employees were potentially exposed to flying objects which can cause struck-by injuries.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Other-than-serious 3 instances 4 exposed
Issued
Apr 16, 2025
Abate by
May 12, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.  On or about March 12, 2025 and at times prior thereto, two relocatable power taps were being used in a manner inconsistent with the listing and labeling for such items.   1. Records / Mail Room: An orange extension cord was plugged into a relocatable power tap near a desk.  2. Warehouse / Fire / Fire cache: A relocatable power tap was affixed to the wall using a metal bracket and screws.   These conditions can cause overloading of circuits or fires. Employees were potentially exposed to electric shock hazards.
Recent events (1)
  • — Z (O) $0

View Department OF Interior - Bureau OF Land Management's full OSHA safety record →