Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CERTIFIED ROOFERS AND GENERAL CONTRACTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CERTIFIED ROOFERS AND GENERAL CONTRACTORS, INC. in 2916 ROYAL TUSCAN LANE, VALRICO, FL 33594 (NAICS 238160). OSHA activity number 348130873.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Certified Roofers and General Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Certified Roofers and General Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2916 ROYAL TUSCAN LANE
City
VALRICO
State
FL
ZIP
33594
Mailing
4331 LYNX PAW TRAIL, VALRICO, FL 33596
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
15
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
May 23, 2025
Penalty
Initial $9,931 · Current $5,959 Reduced
29 CFR  1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:  (a) Below the roofs of Buildings 2916 and 2922 at the site, located at Royal Tuscan Lane, Valrico, FL 33594, on or about 3/25/2025, the employer exposed employees to falling object hazards, in that employees working around roofs are not provided with protective helmets while working around roofs that presented a possible danger of falling materials and tools.
Recent events (2)
  • — I (S) $5958.6
  • — Z (S) $9931

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2025
Abate by
Jun 20, 2025
Penalty
Initial $9,931 · Current $5,959 Reduced
29 CFR  1926.102(a)(1):Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:     (a) On the roofs of Buildings 2916 and 2922 at the site, located at Royal Tuscan Lane, Valrico, FL 33594, on or about 3/25/2025, the employer exposed employees to struck by hazards, in that employees performing roofing work operating pneumatic nail guns were not provided with eye protection.
Recent events (2)
  • — I (S) $5958.6
  • — Z (S) $9931

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
May 23, 2025
Penalty
Initial $11,585 · Current $6,951 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   (a) On the roofs of Buildings 2916 and 2922 at the site, located at Royal Tuscan Lane, Valrico, FL 33594, on or about 3/25/2025, the employer exposed employees to fall hazards, in that employees were performing roofing work on approximately 8.5 ft tall roofs without any fall protection.
Recent events (2)
  • — I (S) $6951
  • — Z (S) $11585

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
May 23, 2025
Penalty
Initial $8,276 · Current $4,966 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) At the roofs of Building 2922 at the site, located at Royal Tuscan Lane, Valrico, FL 33594, on or about 3/25/2025, the employer exposed employees to fall hazards, in that employees used extention ladders that only extended approximately 2 ft over the leading edge to access the roof.
Recent events (2)
  • — I (S) $4965.6
  • — Z (S) $8276

1926.1053 B05 I

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
May 23, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR  1926.1053(b)(5)(i):Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  (a) At the roofs of Buildings 2916 and 2922 at the site, located at Royal Tuscan Lane, Valrico, FL 33594, on or about 3/25/2025, the employer exposed employees to fall hazards, in that ladders used by employees to access roofs at the site were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

View Certified Roofers and General Contractors, INC.'s full OSHA safety record →