PLUMSTEADVILLE, PA —
OSHA Inspection: BAUM PRECISION MACHINING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BAUM PRECISION MACHINING, INC. in 5136 APPLEBUTTER ROAD, PLUMSTEADVILLE, PA 18949 (NAICS 332710). OSHA activity number 348180274.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BAUM PRECISION MACHINING, INC.
- Site address
- 5136 APPLEBUTTER ROAD
- City
- PLUMSTEADVILLE
- State
- PA
- ZIP
- 18949
- Mailing
- 5136 APPLEBUTTER ROAD, PLUMSTEADVILLE, PA 18949
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Jul 3, 2025
- Abate by
- Jul 23, 2025
- Penalty
- Initial $8,276 · Current $4,966 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) 5136 Applebutter Rd. Pipersville, PA - On or about April 15, 2025 the employer failed to establish and implement energy control procedures, employee training, and periodic inspections for employees exposed to unexpected energizing, startup or release of stored energy during servicing or maintenance of machinery.
Recent events (2)
- — I (S) $4966
- — Z (S) $8276
1910.303 B02
- Issued
- Jul 3, 2025
- Abate by
- Jul 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) 5136 Applebutter Rd. Pipersville, PA - On or about April 15, 2025 the oil skimming system was attached to extension cords that were not used or installed in accordance with instructions included in the listing or labeling.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Baum Precision Machining, INC.
View Baum Precision Machining, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348180274.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.