Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OHIO EDISON COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OHIO EDISON COMPANY in 2184 POSSUM RD., SPRINGFIELD, OH 45505 (NAICS 221122). OSHA activity number 348209990.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ohio Edison Company — free Get an email when a new federal OSHA severe-injury report for Ohio Edison Company is published. One employer, no account, unsubscribe in one click.
Establishment
OHIO EDISON COMPANY
Site address
2184 POSSUM RD.
City
SPRINGFIELD
State
OH
ZIP
45505
Mailing
420 YORK ST., SPRINGFIELD, OH 45505
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.335 A01 V

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 6, 2025
Abate by
Jul 25, 2025
Penalty
Initial $7,802 · Current $0 Reduced
29 CFR  1910.335(a)(1)(v): Use of protective equipment - Personal protective equipment. Employees shall wear protective equipment for the eyes or face wherever there is danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion.  a) On or about April 24, 2025, the employer did not ensure that employees exposed to arc flash hazards while disconnecting wires from a Z bar on the secondary side (120/240 volts) were provided with the appropriate personal protective equipment to protect the face, such as a face-shield.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7802

1910.335 A02 II

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 6, 2025
Abate by
Jul 25, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.335(a)(2)(ii):Protective shields, protective barriers, or insulating materials shall be used to protect each employee from shock, burns, or other electrically related injuries while that employee is working near exposed energized parts which might be accidentally contacted or where dangerous electric heating or arcing might occur. When normally enclosed live parts are exposed for maintenance or repair, they shall be guarded to protect unqualified persons from contact with the live parts.  a) On or about 4/24/2025, the employer did not ensure that employees working on energized parts (live z bars of a transformer) utilized protective barriers such as electrical blankets to protect employees from being exposed to a shocks and burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ohio Edison Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348209990.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.