OAK CREEK, WI —
OSHA Inspection: EDD SERVICES LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDD SERVICES LLC in 9691 S. BURRELL ST,, OAK CREEK, WI 53154 (NAICS 238160). OSHA activity number 348211913.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDD SERVICES LLC
- Site address
- 9691 S. BURRELL ST,
- City
- OAK CREEK
- State
- WI
- ZIP
- 53154
- Mailing
- 2247 S. 29TH STREET, MILWAUKEE, WI 53215
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 13
- Ownership type
- A
Citations
7 citations on file for this inspection.
1903.19 C01
- Issued
- Dec 5, 2025
- Abate by
- Dec 29, 2025
- Penalty
- Initial $398 · Current $398
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: (a) EDD Services LLC failed to certify abatement within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation 1, Item 3, a serious violation of 29 CFR 1926.501(b)(15) with an abatement date of September 26, 2025. Citation 1, Item 4 a serious violation of 29 CFR 1926.502(d)(17) with an abatement date of September 26, 2025. Citation 1, Item 5 a serious violation of 29 CFR 1926.1053.(b)(1) with an abatement date of September 26, 2025.
Recent events (1)
- — Z (O) $398
1903.19 D01
- Issued
- Dec 5, 2025
- Abate by
- Dec 29, 2025
- Penalty
- Initial $398 · Current $398
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) EDD Services failed to document abatement within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation 1, Item 2, a serious violation of 29 CFR 1926.501(b)(13) with an abatement date of October 24, 2025. Citation 1, Item 2 a serious violation of 29 CFR 1926.1053(b)(1) with an abatement date of October 9, 2025.
Recent events (1)
- — Z (O) $398
1926.102 A01
- Issued
- Sep 16, 2025
- Penalty
- Initial $6,620 · Current $6,620
General-duty citation text
29 CFR 1926.102(a)(1):The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: (a) On or about April 28, 2025 at 9691 S. Burrell St, Oak Creek, WI, the employer did not ensure employees performing roofing work on a residential construction site with pneumatic nail guns were utilizing safety glasses, exposing employees to eye injuries.
Recent events (1)
- — Z (S) $6620
1926.501 B13
- Issued
- Sep 16, 2025
- Abate by
- Sep 26, 2025
- Penalty
- Initial $11,585 · Current $11,585
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (a) On or about April 28, 2025 at 9691 S. Burrell St, Oak Creek, WI, the employer had not ensured that employees laying shingles a residential property were protected from fall hazards therefore, exposing the employees to a fall hazard of approximately 10 feet to the ground.
Recent events (1)
- — Z (S) $11585
1926.501 B15
- Issued
- Sep 16, 2025
- Abate by
- Sep 26, 2025
- Penalty
- Initial $9,931 · Current $9,931
General-duty citation text
29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: (a) On or about April 28, 9691 S. Burrell St, Oak Creek, WI, employees assisting with roofing activities while working from an Equipter RB4000 elevated dump trailer were not protected from falling to the lower level by guardrails or a personal fall arrest system. This exposed employees to a fall hazard of approximately 12 feet or more onto grass and equipment.
Recent events (1)
- — Z (S) $9931
1926.502 D17
- Issued
- Sep 16, 2025
- Abate by
- Sep 26, 2025
- Penalty
- Initial $6,620 · Current $6,620
General-duty citation text
29 CFR 1926.502(d)(17):The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body narness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. (a) On or about April 28, 2025 at 9691 S. Burrell St, Oak Creek, WI the employer had not ensured the attachment point of the body harness was located in the center of the wearer's back by clipping it to the D-Ring on the harness, while performing roofing work on an existing residential home. This exposed employees to a approximately 10 feet fall.
Recent events (1)
- — Z (S) $6620
1926.1053 B01
- Issued
- Sep 16, 2025
- Penalty
- Initial $11,585 · Current $11,585
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. (a) On or about April 28, 2025 at 9691 S. Burrell St, Oak Creek, WI, the employer did not ensure the Articulating Ladder used by employees to access and egress the residential roof on the front of the home was extended at least three feet above the upper landing. Exposing employees to a fall hazard of approximately 10 feet to the ground below. (b) On or about April 28, 2025 at 9691 S. Burrell St, Oak Creek, WI the employer did not ensure the Articulating Ladder used by employees to access and egress the residential roof on the south end of the home was extended at least three feet above the upper landing. Exposing employees to a fall hazard of approximately 10 feet to the ground below (c) On or about April 28, 2025 at 9691 S. Burrell St, Oak Creek, WI, the employer did not ensure the Articulating Ladder used by employees to access and egress the residential roof on the north end of the home was extended at least three feet above the upper landing. Exposing employees to a fall hazard of approximately 10 feet to the ground below
Recent events (1)
- — Z (S) $11585
More inspections at EDD Services LLC
View EDD Services LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348211913.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.