Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J&M SUPERIOR ROOFING, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of J&M SUPERIOR ROOFING, LLC in 1179 WIND RIVER TRAIL, DRIGGS, ID 83422 (NAICS 238160). OSHA activity number 348231978.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J&M Superior Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for J&M Superior Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1179 WIND RIVER TRAIL
City
DRIGGS
State
ID
ZIP
83422
Mailing
1543 9TH ST, IDAHO FALLS, ID 83404
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 3 instances 5 exposed
Issued
Sep 25, 2025
Abate by
Nov 13, 2025
Penalty
Initial $398 · Current $398
29 CFR  1903.19(c)(1):The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  a) The employer did not provide information about corrective actions for citation 1 item 1 regarding the use of personal protective equipment.  The abatement was due to be completed by August 27, 2025.  b) The employer did not provide information about corrective actions for citation 1 item 2 regarding the use of fall protection during roofing activities.  The abatement was due to be completed by August 27, 2025.  c) The employer did not provide information about corrective actions for citation 1 items 3a and 3b regarding safe set up and use of ladders.  The abatement was due to be completed by August 27, 2025.
Recent events (1)
  • — Z (O) $398

1926.102 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 1, 2025
Abate by
Aug 27, 2025
Penalty
Initial $1,702 · Current $1,702
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles:  (a) On May 07, 2025, the employer did not ensure that its sub-contractor protected its employees who were exposed to eye hazards from flying particles during demolition of the old roof shingles and nails.
Recent events (1)
  • — Z (S) $1702

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 1, 2025
Abate by
Aug 27, 2025
Penalty
Initial $3,405 · Current $3,405
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    (a) On May 07, 2025, the employer did not ensure that its sub-contractor protected its employees who were exposed to falls of approximately 20 feet while performing roofing activities on an 8/12 sloped roof.
Recent events (1)
  • — Z (S) $3405

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 1, 2025
Abate by
Aug 27, 2025
Penalty
Initial $1,702 · Current $1,702
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) On May 07, 2025, the employer did not ensure its subcontractor protected its employees who were exposed to a fall hazard of approximately 10.5 feet while using a ladder to access the roof of a residential home.  The ladder extended approximately 9-inches past the landing surface.
Recent events (1)
  • — Z (S) $1702

1926.1053 B04

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 1, 2025
Abate by
Aug 27, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(4):Ladders were used for purposes other than the purposes for which they were designed:  (a) On May 07, 2025, the employer did not ensure that its sub-contractor protected its employees who were exposed to falls from a height of approximately 10.5 feet while using the upper half of an extension ladder, which had been separated from its base, to access the roof of a residential home. The upper half of the extension ladder did not have feet connected to provide a stable base for use by the employees.
Recent events (1)
  • — Z (S) $0

View J&M Superior Roofing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348231978.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.