Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADUANA INTERNATIONAL FREIGHT FORWARDING SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADUANA INTERNATIONAL FREIGHT FORWARDING SERVICES in #7 ASBC WAREHOUSE HARMON INDUSTRIAL PARK, TAMUNING, GU 96931 (NAICS 484230). OSHA activity number 348260761.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aduana International Freight Forwarding Services — free Get an email when a new federal OSHA severe-injury report for Aduana International Freight Forwarding Services is published. One employer, no account, unsubscribe in one click.
Site address
#7 ASBC WAREHOUSE HARMON INDUSTRIAL PARK
City
TAMUNING
State
GU
ZIP
96931
Mailing
P.O. BOX 27544 COMF, BARRIGADA, GU 96921
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484230
Employees
14
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 9, 2025
Penalty
Initial $4,729 · Current $3,310 Reduced
29 CFR  OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by and/or crushed-by hazards.   a. Throughout the Warehouse: The storage rack base plates were not anchored to the floor to prevent movement. Employees were exposed to struck-by and crushed-by hazards.  b. In the front, orange rack area: A storage rack with two damaged legs was used to store large boxes and furniture parts on pallets. Employees were exposed to struck-by and crushed-by hazards.
Recent events (2)
  • — I (S) $3310.3
  • — Z (S) $4729

1910.37 A03

Other-than-serious 1 instance 3 exposed
Issued
Jul 9, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  The warehouse emergency exit: Access to the exit door was prohibited by several large tires blocking the door and by a bar installed at the door.  Employees were exposed to fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 Q01

Other-than-serious 1 instance 1 exposed
Issued
Jul 9, 2025
Abate by
Aug 25, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  Komatsu Forklift: The horn and one back up light were non-operational..  Employees were exposed to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 3 exposed
Issued
Jul 9, 2025
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a.  In front of the electrical panel to the left of the red air compressor: Mops and brooms were blocking the access to the electrical panel.  Employees were exposed to electrical hazards.  b. Near emergency exit: Boxes of parts were stored in front of the  electrical panel, prohibiting access to the panel.  Employees were exposed to electrical and fire hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 3 exposed
Issued
Jul 9, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Warehouse, behind the red air compressor: In the electrical panel, there were two switches removed, exposing the live parts of the panel board.  Employees were exposed to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Aduana International Freight Forwarding Services's full OSHA safety record →