MELROSE PARK, IL —
OSHA Inspection: INTERLAKE MECALUX, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of INTERLAKE MECALUX, INC. in 1600 N. 25TH AVE., MELROSE PARK, IL 60160 (NAICS 423830). OSHA activity number 348382839.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERLAKE MECALUX, INC.
- Site address
- 1600 N. 25TH AVE.
- City
- MELROSE PARK
- State
- IL
- ZIP
- 60160
- Mailing
- 1600 N. 25TH AVE., MELROSE PARK, IL 60160
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423830
- Employees
- 380
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Sep 4, 2025
- Abate by
- Sep 30, 2025
- Penalty
- Initial $16,550 · Current $11,585 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Warehouse- On or about July 15, 2025, employees were exposed to machine hazards associated with the clamping mechanism and cutting blade while performing maintenance and servicing tasks on roll forming machine, such as performing setups. The employer did not implement energy control application steps as the machine was not shut down and deenergized to perform setup or adjustments [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $11585
- — Z (S) $16550
More inspections at Interlake Mecalux, INC.