NORTH RICHLAND HILLS, TX —
OSHA Inspection: TYSON PREPARED FOODS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TYSON PREPARED FOODS INC. in 6350 BROWNING COURT, NORTH RICHLAND HILLS, TX 76180 (NAICS 311612). OSHA activity number 348399619.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TYSON PREPARED FOODS INC.
- Site address
- 6350 BROWNING COURT
- City
- NORTH RICHLAND HILLS
- State
- TX
- ZIP
- 76180
- Mailing
- 6350 BROWNING COURT, NORTH RICHLAND HILLS, TX 76180
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 340
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.119 D03 II
- Issued
- Jan 21, 2026
- Abate by
- Mar 12, 2026
- Penalty
- Initial $5,674 · Current $3,404 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that the equipment complies with recognized and generally accepted good engineering practices. (a) On or about July 23, 2025, Piping was routed through the machinery room wall with an unsealed penetration that did not maintain tight construction of the machinery room, without documentation that the room complied with the employer's selected RAGAGEP, IIAR 2 (2021), Standard for Design of Safe Closed-Circuit Ammonia Refrigeration Systems, Section 6.6.2; and (b) On or about July 23, 2025, Conduits were routed through the louver in the machinery room without documentation that the room complied with the employer's chosen RAGAGEP, IIAR 2 (2021) Standard for Safe Design of Closed Circuit Ammonia Refrigeration Systems, Sections 6.14.5.4.
Recent events (2)
- — I (O) $3404.4
- — Z (S) $5674
More inspections at Tyson Prepared Foods INC.
View Tyson Prepared Foods INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348399619.