SCHAUMBURG, IL —
OSHA Inspection: GONNELLA FROZEN PRODUCTS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GONNELLA FROZEN PRODUCTS, LLC in 1117 WILEY ROAD, SCHAUMBURG, IL 60173 (NAICS 311999). OSHA activity number 348493156.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GONNELLA FROZEN PRODUCTS, LLC
- Site address
- 1117 WILEY ROAD
- City
- SCHAUMBURG
- State
- IL
- ZIP
- 60173
- Mailing
- 1117 WILEY ROAD, SCHAUMBURG, IL 60173
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 187
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 D
- Issued
- Dec 23, 2025
- Penalty
- Initial $165,514 · Current $99,999 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (a) Bakeshop- On September 8, 2025, employees were exposed to caught in hazard at the press board on the Rheon South molding station. The employer failed to implement energy control application steps as the press board was not de-energized to protect employees from caught in hazards when reaching in to manually scrape dough buildup [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine shutdown [1910.147(d)(2)], machine isolation [1910.147(d)(3)], lock-out/tag-out device application [1910.147(d)(4)], dissipation or residual energy [1910.147(d)(5)(i), and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (W) $99999
- — Z (W) $165514
More inspections at Gonnella Frozen Products, LLC
View Gonnella Frozen Products, LLC's full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348493156.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.