FREMONT, OH —
OSHA Inspection: STYLE CREST ENTERPRISES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STYLE CREST ENTERPRISES, INC. in 600 HAGERTY DR., FREMONT, OH 43420 (NAICS 326199). OSHA activity number 348903923.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STYLE CREST ENTERPRISES, INC.
- Site address
- 600 HAGERTY DR.
- City
- FREMONT
- State
- OH
- ZIP
- 43420
- Mailing
- 600 HAGERTY DRIVE, FREMONT, OH 43420
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 130
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jun 8, 2026
- Penalty
- Initial $9,458 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Style Crest Enterprises, Inc. - Fremont, Ohio: On or about April 22, 2026, the employer did not ensure that periodic inspections of the hazardous energy control procedure for the Line 7 extrusion line were conducted to ensure that operators were protected from pinch points and hazards associated with moving parts during set-up adjustments for the line.
Recent events (2)
- — I (O) $0
- — Z (S) $9458
1910.147 D
- Issued
- Jun 8, 2026
- Abate by
- Jun 25, 2026
- Penalty
- Initial $9,458 · Current $4,727 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Style Crest Enterprises, Inc. - Fremont, Ohio: On or about April 22, 2026, the employer did not ensure that hazardous energy, including the movement of vinyl siding product on the Line 7 extrusion line, was controlled to prevent ingoing nip point hazards on the weep hole punch mechanism, while operators made set-up adjustments for the line. The employer did not implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $4727
- — Z (S) $9458
More inspections at Style Crest Enterprises, INC.
View Style Crest Enterprises, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348903923.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.