Safety Incidents OSHA Severe Injury Reports · 2015–2025
105,991Records 70,589Employers 85,836Hospitalizations 27,959Amputations 2015-01-01 2025-11-30

Viking Fabrication Services LLC

Caught, entangled in running powered equipment normal operation · Amputations involving bone loss

Federal OSHA recorded a severe workplace injury at Viking Fabrication Services LLC, 12360 E 46th Ave Suite 400, DENVER, COLORADO 80239 on , Amputations involving bone loss, affecting the finger or thumb tip(s), nail(s).

Watch Viking Fabrication Services LLC for free Get an email when a new federal OSHA severe-injury report for Viking Fabrication Services LLC is published. One employer, no account, unsubscribe in one click.

An employee was using a pipe groover machine to roll a groove at the end of a 10-foot-long steel pipe. Their gloved left index finger was caught between the pipe and the adjustable pipe guard, resulting in a partial fingertip amputation through the distal phalanx.

Amputation Finger or thumb tip(s), nail(s) Bending, rolling, shaping, stamping machinery n.e.c.