Stephenville, TX —
OSHA Injury Report: Stephenville Facility
Injury · Other recordable case
At a glance
On , an injury at Stephenville Facility in Stephenville, TX 76401 resulted in other recordable case. Employee was assembler in bits, rock drill, oil and gas field-type, manufacturing.
Where did this happen?
- Establishment
- Stephenville Facility
- Parent company
- TechnipFMC
- Street
- 2825 West Washington Street
- City
- Stephenville
- State
- TX
- ZIP
- 76401
- On-site location
- Wellhead Assembly
What was the outcome?
- Outcome
- Other recordable case (code 4)
- Type
- Injury (code 1)
Before the incident
A Wellhead Assembly Technician (Employee ID 30803370) was using a motorized pallet jack to move a part from the north tester to the [REDACTED]-prep area. Once he was in the [REDACTED]-prep area he started backing up the pallet jack to get it into position.
What happened
He was maneuvering the pallet jack between the center assembly staging area and the south tester. The test door was in the open position causing a tight area. This has been done on multiple occasions without incident. The employee thought that there was enough room to get by and that is when he pinched the back side of his left hand between the handle of the pallet jack and the metal safety ears on the south test door.
Injury or illness
contusion left hand
Object or substance involved
pinch point while operating powered pallet jack
Summary line
Left hand contusion bumped into door
Employee and industry
- Job description
- Assembler
- SOC code
- 51-2099 — Assemblers and Fabricators, All Other
- NAICS code
- 333132 — Bits, rock drill, oil and gas field-type, manufacturing
- NAICS vintage
- 2022
- Avg employees
- 424
- Total hours worked
- 891663
- EIN
- 364412642
- Establishment ID
- 217638
- Employer case #
- 1
When (timing detail)
- Date of incident
- Shift started
- 15:00:00.000
- Time of incident
- 15:30:00.000
- Submitted
- 30JAN24:15:47:00
Source
Data from OSHA ITA Form 300/301 electronic submissions, filing year unspecified. ITA Case Detail records are establishment-reported submissions, not OSHA inspections — no per-record IMIS deep link exists.