CANTON, SD —
OSHA Inspection: ADAMS THERMAL SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ADAMS THERMAL SYSTEMS, INC. in 47920 FIFTH STREET, CANTON, SD 57013 (NAICS 332313). OSHA activity number 102759271.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADAMS THERMAL SYSTEMS, INC.
- Site address
- 47920 FIFTH STREET
- City
- CANTON
- State
- SD
- ZIP
- 57013
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- SIC code (legacy)
- 3443
- Employees
- 200
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 18, 2005
- Abate by
- Mar 22, 2005
- Penalty
- Initial $3,500 · Current $1,400 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to amputation hazards created by a lack of training: (a) On or about 09/30/04 an employee suffered an amputation injury while operating the Chicago press brake in the prototype room. (b) On or about 10/02/04 an employee suffered an amputation injury while operating the DR assembly machine in the aluminum vacuum brake division. Among other methods, one feasible and acceptable abatement method to correct this hazard is to establish an employee training program that ensures that all employees, both new hires and current employees, receive the training necessary to ensure that employees understand the workings of the machines and equipment they are operating in every department, safety devices on the machines and equipment designed to protect the employees, and the potential hazards posed by the machines and equipment the employees are operating. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Sample Abatement Certification Letter").tion
Recent events (2)
- — I (S) $1400.00
- — Z (S) $3500.00
1910.106 E02 II
- Issued
- Feb 18, 2005
- Abate by
- Mar 22, 2005
- Penalty
- Initial $1,050 · Current $420 Reduced
Recent events (2)
- — I (S) $420.00
- — Z (S) $1050.00
1910.212 A01
- Issued
- Feb 18, 2005
- Abate by
- Jul 25, 2005
- Penalty
- Initial $3,500 · Current $1,400 Reduced
Recent events (3)
- — P (S) $1400.00
- — I (S) $1400.00
- — Z (S) $3500.00
1910.215 A04
- Issued
- Feb 18, 2005
- Abate by
- Mar 22, 2005
- Penalty
- Initial $1,050 · Current $420 Reduced
Recent events (2)
- — I (S) $420.00
- — Z (S) $1050.00
1910.215 B09
- Issued
- Feb 18, 2005
- Abate by
- Mar 22, 2005
1910.212 A03 II
- Issued
- Feb 18, 2005
- Abate by
- Feb 24, 2005
- Penalty
- Initial $56,000 · Current $22,400 Reduced
Recent events (2)
- — I (W) $22400.00
- — Z (W) $56000.00
More inspections at Adams Thermal Systems, INC.
View Adams Thermal Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332313)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 102759271.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.