BRYAN, OH ·
OSHA Inspection: MANUFACTURED HOUSING ENTERPRISES INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MANUFACTURED HOUSING ENTERPRISES INC. in 09302 ST. RT. 6, BRYAN, OH 43506 (NAICS 321991). OSHA activity number 305115453.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUFACTURED HOUSING ENTERPRISES INC.
- Site address
- 09302 ST. RT. 6
- City
- BRYAN
- State
- OH
- ZIP
- 43506
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- SIC code (legacy)
- 2451
- Employees
- 200
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 14, 2003
- Abate by
- Aug 29, 2003
- Penalty
- Initial $4,000 · Current $2,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: a.On or about October 23, 2002, employees were exposed to falling loads and/or falling hoist parts: Floor Assembly area: The hoist used in all areas of assembly were not kept in good repair in that the following deficiencies were noted: (a) the spreader type lifting devices and the spreader bar lifting devices were not marked with their weight and lifting capacities and no rated load tests were conducted on these devices with a written report to confirm the device lifting capacity. (b) One device utilized to lift floor assemblies exhibited damage in that the aluminum frames were bent evidencing possible overload of the device. Additional abatement information is required for this item. One method of abatement is to ensure each lifting device is manufactured and tested in accordance with ANSI B30.20a-2001.
Recent events (2)
- · R (S) $2500.00
- · Z (S) $4000.00
1910.23 C01
- Issued
- Jan 14, 2003
- Abate by
- Mar 4, 2003
- Penalty
- Initial $3,500 · Current $2,200 Reduced
Recent events (2)
- · R (S) $2200.00
- · Z (S) $3500.00
1910.132 A
- Issued
- Jan 14, 2003
- Abate by
- Aug 29, 2003
- Penalty
- Initial $3,500 · Current $2,200 Reduced
Recent events (2)
- · R (S) $2200.00
- · Z (S) $3500.00
1910.184 C09
- Issued
- Jan 14, 2003
- Abate by
- Aug 29, 2003
- Penalty
- Initial $3,500 · Current $2,200 Reduced
Recent events (2)
- · R (S) $2200.00
- · Z (S) $3500.00
More inspections at Manufactured Housing Enterprises INC.
View Manufactured Housing Enterprises INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 305115453.