Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: DURA-BOND PIPE LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DURA-BOND PIPE LLC in 2716 SOUTH FRONT STREET, STEELTON, PA 17113 (NAICS 332812). OSHA activity number 308472307.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dura-Bond Pipe LLC for free Get an email when a new federal OSHA severe-injury report for Dura-Bond Pipe LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DURA-BOND PIPE LLC
Site address
2716 SOUTH FRONT STREET
City
STEELTON
State
PA
ZIP
17113
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
SIC code (legacy)
3479
Employees
60
Ownership type
Private (A)
Industry flags
Manufacturing safety.

12 citations on file for this inspection.

5(a)(1)

Serious Gravity 01 4 instances 30 exposed
Issued
Aug 12, 2005
Abate by
Sep 8, 2005
Penalty
Initial $525 · Current $340 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to hazards of overloading and/or dropping slipping, or
swinging loads:
(a)Expanded Pipe Mill, Up River - Employees used a vacuum lifting device,
manufactured by Vac-U-Lift to move sheets of steel.  This below-the-hook
lifting
device did not have a permanently affixed identification stating the rated
capacity
legibly marked on the main structure and did not have an inspection
record, on
or about May 11, 2005.
(b)Expanded Pipe Mill, Down River - Employees used two (2) spreader bars to
move pipe throughout the manufacturing process.  These below-the-hook,
spreader beams/load supporting lifting devices did not have permanent
markings
displaying the rated capacity of the lifting devices, an identification
for
each
lifting device or inspection records, on or about May 11, 2005.
(c)Painting/Coating Bay, Down River - Employees used a H pile hook to move
sheet
pile.  This below-the-hook, load supporting lifter did not have a
nameplate or
other permanent markings displaying the manufacturer's name, address,
serial
number or rated load.  In addition, there were no inspection records for
the hook,
on or about May 11, 2005.
(d)Outside Rail Loading Area - Employees used a crane equipped with
electromagnetic lifters to move pipe from a conveyor line to rail cars,
there were
no inspection records for the magnet device, on or about May 11, 2005.
Among other methods, one feasible and acceptable abatement method to
correct these
hazards includes:
As specified in Below-The-Hook Lifting Devices, ANSI/ASME B30.20-1999, for
load supporting lifters, the rated load of the lifting device shall be
marked on the
main structure where it is visible.  An identification of the lifting
device shall be
listed on a nameplate or other permanent marking displaying the
manufacturer's
name, address, serial number, lifter weight and rated load.
As specified in Below-The-Hook Lifting Devices, ANSI/ASME B30.20-1999, for
vacuum lifting devices, the rated load, maximum width, maximum length and
minimum thickness of the load shall be legibly marked on the main
structure.
As specified in Below-The-Hook Lifting Devices, ANSI/ASME B30.20-1999, for
load supporting lifters, vacuum lifting devices and lifting magnets,
conduct
frequent and periodic inspections for each Below-The-Hook lifting device.
Record periodic inspection results.  It is acceptable to make an external
code
mark on the load supporting lifter or vacuum lifting device as an
acceptable
identification in lieu of records.  VERIFICATION REQUIRED
Recent events (2)
  • · I (S) $340.00
  • · Z (S) $525.00

1910.242 B

Serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 8, 2005
Penalty
Initial $525 · Current $340 Reduced
Recent events (2)
  • · I (S) $340.00
  • · Z (S) $525.00

1910.1200 E01

Serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005
Penalty
Initial $525 · Current $345 Reduced
Recent events (2)
  • · I (S) $345.00
  • · Z (S) $525.00

1910.1200 E01 I

Serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.1200 H

Serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.134 C01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.134 E01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.134 F02

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.134 K01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.145 C03

Other-than-serious Gravity 01 2 instances 2 exposed
Issued
Aug 12, 2005
Abate by
Sep 14, 2005

1910.179 J02 III

Other-than-serious Gravity 01 1 instance 30 exposed
Issued
Aug 12, 2005
Abate by
Sep 8, 2005

1910.179 M01

Other-than-serious Gravity 01 1 instance 30 exposed
Issued
Aug 12, 2005
Abate by
Sep 8, 2005

View Dura-Bond Pipe LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 308472307.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.