Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: YOUNG GALVANIZING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of YOUNG GALVANIZING, INC. in 8281 MERCER STREET, PULASKI, PA 16143 (NAICS 332812). OSHA activity number 309332229.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Young Galvanizing, INC. — free Get an email when a new federal OSHA severe-injury report for Young Galvanizing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8281 MERCER STREET
City
PULASKI
State
PA
ZIP
16143
Mailing
P.O. BOX 334, PULASKI, PA 16143
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
SIC code (legacy)
3479
Employees
73
Ownership type
A

28 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 2 instances 30 exposed
Issued
Jul 7, 2006
Abate by
Jul 12, 2006
Penalty
Initial $700 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were potentially exposed to fire and explosion hazards from the ignition
of potential natural gas
leaks due to the lack of a readily accessible manual shut-off valves and
improperly supported
natural gas piping::
A.) Dirty Side /Area Near the Electrical Panel Enclosed By A Cage: A
readily
accessible manual shut-off valve was not installed on the natural gas
piping within at least
6-feet of the natural gas fired space heater.  The existing shut-off
required
tools to be
operated.
B.) Area Near the Checker Shack: A readily accessible manual shut-off
valve was not
installed on the natural gas piping within at least 6-feet of the natural
gas fired space
heater.  The existing shut-off required tools to be operated.  In
addition, the natural gas
piping that led from the heater, across the floor, and up the wall was not
adequately
supported/restrained.
ABATEMENT NOTE:
Among other methods, feasible and acceptable means to correct the
condition include
complying with the applicable requirements outlined in the National Fuel
Gas Code
(NFPA 54/ANSI Z223.1 AND/OR  the International Fuel Gas Code.
Shutoff Valves:
National Fuel Gas Code (NFPA 54/ANSI Z223.1) Sections 5.12 shutoff valves
shall be
selected given consideration to pressure drop, service involved, emergency
use, and
reliability of operation.
National Fuel Gas Code (NFPA 54/ANSI Z223.1) AND/OR the International Fuel
Gas
Code requires the manual shut-off valve to be separate from the equipment
served,
readily accessible, and located at least within 6-feet of the equipment
served.
Pipe Support, Hangers, and Anchors:
National Fuel Gas Code (NFPA 54/ANSI Z223.1) Sections 7.2.6.1  (a) Piping
shall be
supported with hooks, brackets, straps, bands, or hangers suitable for the
size of the
piping, of adequate strength/quality, and located at intervals so as to
prevent or damp out
excessive vibration.  Piping hsall be anchored to prevent undo strain on
connected
equipment. (b) Spacing of supports shall not be greater than 6-foot to
10-foot
intervals
(Based on pipe diameter and Table 7.2.6)
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $700.00

1910.22 C

Serious Gravity 02 1 instance 5 exposed
Issued
Jul 7, 2006
Abate by
Jul 12, 2006
Penalty
Initial $700 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $700.00

1910.23 A08

Serious Gravity 01 1 instance 5 exposed
Issued
Jul 7, 2006
Abate by
Jul 12, 2006
Recent events (2)
  • — I (S)
  • — Z (S)

1910.22 B01

Serious Gravity 01 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Recent events (2)
  • — I (S)
  • — Z (S)

1910.176 B

Serious Gravity 02 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Recent events (2)
  • — I (S)
  • — Z (S)

1910.37 A04

Serious Gravity 01 3 instances 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Penalty
Initial $525 · Current $394 Reduced
Recent events (2)
  • — I (S) $394.00
  • — Z (S) $525.00

1910.37 A03

Serious Gravity 01 1 instance 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Recent events (2)
  • — I (S)
  • — Z (S)

1910.37 B02

Serious Gravity 01 1 instance 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Recent events (2)
  • — I (S)
  • — Z (S)

1910.147 C04 II

Serious Gravity 02 1 instance 6 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006
Penalty
Initial $700 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $700.00

1910.147 C02 II

Serious Gravity 01 1 instance 6 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006

1910.147 C06 IA

Serious Gravity 02 1 instance 6 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006

1910.333 B02 IVB

Serious Gravity 02 1 instance 6 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006

1910.179 L02 ID

Serious Gravity 02 1 instance 6 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006
Penalty
Initial $700 · Current $525 Reduced
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $700.00

1910.179 L02 IE

Serious Gravity 02 1 instance 6 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006

1910.179 G01 V

Serious Gravity 05 3 instances 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Penalty
Initial $1,225 · Current $919 Reduced
Recent events (2)
  • — I (S) $919.00
  • — Z (S) $1225.00

1910.179 G02 II

Serious Gravity 05 3 instances 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

1910.179 G01 V

Serious Gravity 02 1 instance 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

1910.179 N03 IX

Serious Gravity 03 1 instance 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Penalty
Initial $875 · Current $656 Reduced
Recent events (2)
  • — I (S) $656.00
  • — Z (S) $875.00

5(a)(1)

Serious Gravity 03 1 instance 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were potentially exposed to blunt force trauma injuries from dropped,
falling, and toppling crane
loads in that care was not taken to ensure the load did not contact any
obstructions and there was
no sudden acceleration or deceleration of the moving load [in accordance
with ANSI B30.11
Monorail Cranes Section 11-3.2.3 (c)(1)-(2)]:
A.) Young Galvanizing, Inc.- Pulaski, PA-Crane Program/Quench Tank Area:
The
crane's load was knocked against the quench tank to dislodge excess
galvanizing
material.
ABATEMENT NOTE:
Among other methods, feasible and acceptable means to correct the
condition include
training the operators in accordance with the requirements noted in ANSI
B30.11
Monorail Cranes Section 11-3.2.3 (c)(1)-(2) which states - care will be
taken to ensure
that the load does not contact any obstructions and there is no sudden
acceleration or
deceleration of the moving load.g

1910.179 N02 II

Serious Gravity 10 2 instances 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006
Penalty
Initial $2,500 · Current $1,875 Reduced
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $2500.00

1910.179 B08

Serious Gravity 05 1 instance 20 exposed
Issued
Jul 7, 2006
Abate by
Aug 23, 2006

1910.180 D03

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006
Penalty
Initial $2,500 · Current $1,875 Reduced
Recent events (2)
  • — I (S) $1875.00
  • — Z (S) $2500.00

1910.180 B02

Serious Gravity 02 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

1910.180 C02

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

1910.180 H02 II

Serious Gravity 10 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

1910.147 C05 II

Serious Gravity 02 1 instance 10 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

1910.215 B09

Serious Gravity 01 1 instance 4 exposed
Issued
Jul 7, 2006
Abate by
Jul 12, 2006
Penalty
Initial $525 · Current $394 Reduced
Recent events (2)
  • — I (S) $394.00
  • — Z (S) $525.00

1910.215 D03

Serious Gravity 01 2 instances 4 exposed
Issued
Jul 7, 2006
Abate by
Aug 2, 2006

View Young Galvanizing, INC.'s full OSHA safety record →