PULASKI, PA —
OSHA Inspection: YOUNG GALVANIZING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of YOUNG GALVANIZING, INC. in 8281 MERCER STREET, PULASKI, PA 16143 (NAICS 332812). OSHA activity number 345021125.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YOUNG GALVANIZING, INC.
- Site address
- 8281 MERCER STREET
- City
- PULASKI
- State
- PA
- ZIP
- 16143
- Mailing
- P.O. BOX 334, PULASKI, PA 16143
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 103
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- May 10, 2021
- Abate by
- Jun 4, 2021
- Penalty
- Initial $5,969 · Current $1,800 Reduced
General-duty citation text
29 CFR OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burn hazards from hot element of an electric air heater: A.) Young Galvanizing, Inc., 8281 Mercer Street, Pulaski, PA 16143, maintenance shop, on or about November 12, 2020 and times prior thereto: Employees were using an electric air heater to heat the maintenance shop. The hot heating elements were not supported at the top and were sagging forward. The hot heating elements were leaning up against the guard and outside of the guard. The guard openings were 2.5-inches by 2.5-inches. The position of the guard and openings of the guarding made the guarding ineffective.
Recent events (2)
- — I (S) $1800
- — Z (S) $5969
1910.334 A02 II
- Issued
- May 10, 2021
- Abate by
- Jun 4, 2021
- Penalty
- Initial $4,476 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: A.) Young Galvanizing, Inc., 8281 Mercer Street, Pulaski, PA 16143, north side of the building, on or about November 12, 2020 and times prior thereto: Employees were using a Milwaukee Grinder (Cat. No. 6141-31, S/N: H39CD194400079). The outer jacket of the flexible cord was frayed. B.) Young Galvanizing, Inc., 8281 Mercer Street, Pulaski, PA 16143, north side of the building, on or about November 12, 2020 and times prior thereto: Employees were using a Milwaukee Grinder (Cat. No. and Serial Number illegible). The outer jacket of the flexible cord was frayed. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $4000
- — Z (S) $4476
1910.303 B07
- Issued
- May 10, 2021
- Abate by
- Jun 4, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner: A.) Young Galvanizing, Inc., 8281 Mercer Street, Pulaski, PA 16143, north side of the building, on or about November 12, 2020 and times prior thereto: Employees were using a Milwaukee Grinder (Cat. No. 6141-31, S/N: H39CD194400079). The flexible cord was repaired with a wire cap mid-cord and the repair was wrapped in electrical tape. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 II
- Issued
- May 10, 2021
- Abate by
- Jun 4, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: A.) Young Galvanizing, Inc., 8281 Mercer Street, Pulaski, PA 16143, outside, on or about November 12, 2020 and times prior thereto: Employees were using a Blackweb Portable Bluetooth Party Speaker (M/N: BWA17AA006). The outer housing of the speaker was cracked and the power receptacle was hanging out of the speaker, exposing the inner insulated wiring. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- May 10, 2021
- Abate by
- Jun 4, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): A.) Young Galvanizing, Inc., 8281 Mercer Street, Pulaski, PA 16143, on or about November 12, 2020 and times prior thereto: Employees were using a Clark forklift for work operation including, but not limited to, moving and stacking bridge floors and 24-foot rebar rods. The windshield, rear window and lower side/door window were cracked and damaged. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Young Galvanizing, INC.
View Young Galvanizing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345021125.