LITTLETON, WV —
OSHA Inspection: NOMAC DRILLING, LLC
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of NOMAC DRILLING, LLC in RIG 241, LITTLETON, WV 26581 (NAICS 213111). OSHA activity number 311686992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NOMAC DRILLING, LLC
- Site address
- RIG 241
- City
- LITTLETON
- State
- WV
- ZIP
- 26581
- Mailing
- 171 LOCUS AVENUE EXTENSION, MT. MORRIS, PA 15349
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- SIC code (legacy)
- 1381
- Employees
- 21
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 10, 2009
- Abate by
- May 14, 2010
- Penalty
- Initial $7,000 · Current $4,900 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were likely to cause death or serious physical harm to the employees in that employees were exposed to fire, explosion and/or release of toxic fumes due to the uncontrolled release of pressurized gas or fumes: (a)NOMAC Drilling, Rig #241 - Employees were exposed to hazards such as but not limited to, toxic fumes, fire, and explosions while performing work on the rig floor. Employees were overcome by toxic fumes coming out the end of the drill string while tripping pipe, well control was not maintained at all times, as determined on 05/21/09. NOTE: Among other methods, one or more feasible and acceptable abatement method to prevent this hazard is to; a) ensure proper well control equipment is on site and utilized to maintain well control as addressed in Recommended Practice for Occupational Safety for Oil and Gas Well Drilling and Servicing Operations, American Petroleum Institute (API) Recommended Practice 54, Third Edition, August 1999, paragraph 6.1.1 "Well control shall be maintained at all times. Consideration shall be made to ensure appropriate equipment and materials are on location and operational before work commences.", b) install the T.I.W valve and close off valve at the first indication of abnormal smoke or odor coming out of the drill string when tripping out, c) use a high temp rated float valve, d) install a fire stop or fire float in the drill string, e) install additional drill string floats, f) use nitrogen injection down the drill pipe when MWD is used, and/or g) add/Install a shear ram to the Blow out Preventer (BOP). ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
- — F (S) $4900.00
- — Z (S) $7000.00
More inspections at Nomac Drilling, LLC