OSHA Inspection: NOMAC DRILLING, LLC

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of NOMAC DRILLING, LLC in RIG 241, LITTLETON, WV 26581 (NAICS 213111). OSHA activity number 311686992.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nomac Drilling, LLC — free Get an email when a new federal OSHA severe-injury report for Nomac Drilling, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
NOMAC DRILLING, LLC
Site address
RIG 241
City
LITTLETON
State
WV
ZIP
26581
Mailing
171 LOCUS AVENUE EXTENSION, MT. MORRIS, PA 15349
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
SIC code (legacy)
1381
Employees
21
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 5 exposed
Issued
Nov 10, 2009
Abate by
May 14, 2010
Penalty
Initial $7,000 · Current $4,900 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were likely to cause death or serious physical harm to the employees
in that employees
were exposed to fire, explosion and/or release of toxic fumes due to the
uncontrolled release
of pressurized gas or fumes:
(a)NOMAC Drilling, Rig #241 - Employees were exposed to hazards such as but
not limited to, toxic fumes, fire, and explosions while performing work on
the
rig floor.  Employees were overcome by toxic fumes coming out the end of
the drill string while tripping pipe, well control was not maintained at
all
times, as determined on 05/21/09.
NOTE: Among other methods, one or more feasible and acceptable abatement
method to
prevent this hazard is to; a) ensure proper well control equipment is on
site and utilized to
maintain well control as addressed in Recommended Practice for
Occupational Safety for Oil
and Gas Well Drilling and Servicing Operations, American Petroleum
Institute (API)
Recommended Practice 54, Third Edition, August 1999, paragraph 6.1.1 "Well
control
shall
be maintained at all times.  Consideration shall be made to ensure
appropriate equipment and
materials are on location and operational before work commences.", b)
install the T.I.W
valve and close off valve at the first indication of abnormal smoke or
odor coming out of the
drill string when tripping out, c) use a high temp rated float valve, d)
install a fire stop or
fire float in the drill string, e) install additional drill string floats,
f) use nitrogen injection
down the drill pipe when MWD is used, and/or g) add/Install a shear ram to
the Blow out
Preventer (BOP).
ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (2)
  • — F (S) $4900.00
  • — Z (S) $7000.00

View Nomac Drilling, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 311686992.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.