OSHA Inspection: STANDARD REGISTER COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STANDARD REGISTER COMPANY in 121 MOUNT ZION ROAD, YORK, PA 17402 (NAICS 323116). OSHA activity number 314244823.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Standard Register Company — free Get an email when a new federal OSHA severe-injury report for Standard Register Company is published. One employer, no account, unsubscribe in one click.
Site address
121 MOUNT ZION ROAD
City
YORK
State
PA
ZIP
17402
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323116
SIC code (legacy)
2761
Employees
110
Ownership type
A
Industry flags
Manufacturing safety.

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 1 instance 2 exposed
Issued
Jul 21, 2011
Abate by
Dec 31, 2012
Penalty
Initial $3,400 · Current $2,720 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to severe burn injuries from the
potential dust explosion that could have resulted from, or have been
exacerbated by, recycling the air back
into the building without a high speed abort gate, a lack of a back flash
damper and the lack of deflagration
vents for the dust collector:
(a)Standard Register Company - The dust collection system was used to
collect paper dust.  The
dust collection system, duct work leading to the dust collector and the
recycled air were not
protected by a deflagration vent,  a back flash damper and a high speed
abort gate system in
the event of a fire or explosion, on or about April 1, 2011.
ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement
method to
correct this hazard includes following the National Fire Protection
Association
(NFPA) 654, Standard
for the Prevention of Fire and Dust Explosions from the Manufacturing,
Processing, and Handling of
Combustible Particulate Solids, 2006 Edition, including, but not limited
to installing a high speed abort
system on the return air duct work, installing a back flash damper on the
inlet side, a deflagration
system or a suppression system on the dust collector and/or duct work.
All proposed control measures shall be approved for each particular use by
a competent engineer or
other technically qualified person.  Ninety (90) day progress reports are
required during
the abatement period.
*STEP 1
Submit to the Area Director a written, detailed plan of abatement
outlining a schedule for the
implementation of engineering and/or administrative measures to control
employee exposure to
hazardous substances as referenced in this citation.
This plan shall include, at a minimum, target dates for the following
actions which must be consistent
with the abatement dates required by this citation:
1.Evaluation of engineering/administrative control options.
2.Selection of optimum control methods and completion of design.
3.Procurement, installation and operation of selected control measures;
and
4.Acceptance or modification/redesign of controls.
*STEP 2
Abatement shall have been completed by the implementation of feasible
engineering upon verification
of their effectiveness in achieving compliance.
Date by Which Violation Must be Abated:STEP - 1  10/22/11
Date by Which Violation Must be Abated:STEP - 2  07/23/12
Abatement certification required within 10 days after abatement date. The
certification shall
include a statement that abatement is complete, date and method of
abatement, and states
employees and their representatives were informed of this abatement.
Recent events (3)
  • — P (S) $2720.00
  • — I (S) $2720.00
  • — Z (S) $3400.00

1910.22 A01

Other-than-serious Gravity 05 1 instance 2 exposed
Issued
Jul 21, 2011
Abate by
Jul 26, 2011
Penalty
Initial $3,400 · Current $2,720 Reduced
Recent events (2)
  • — I (O) $2720.00
  • — Z (S) $3400.00

View Standard Register Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 314244823.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.