Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: OREGON AIR NATIONAL GUARD 142 FW

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OREGON AIR NATIONAL GUARD 142 FW in 6801 NE CORNFOOT RD LOGISTICS SQUADRON, PORTLAND, OR 97218 (NAICS 493190). OSHA activity number 331067785.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oregon AIR National Guard 142 FW — free Get an email when a new federal OSHA severe-injury report for Oregon AIR National Guard 142 FW is published. One employer, no account, unsubscribe in one click.
Site address
6801 NE CORNFOOT RD LOGISTICS SQUADRON
City
PORTLAND
State
OR
ZIP
97218
Mailing
6801 NE CORNFOOT RD, PORTLAND, OR 97218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493190
Employees
40
Ownership type
D

2 citations on file for this inspection.

1910.213 B03

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 19, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.213(b)(3):     On applications where injury to the operator might result if motors were to restart after powerfailures, provision shall be made to prevent machines from automatically restarting upon restoration of power.    Logistic Warehouse wood shop:  On or about September 7, 2011 and times prior thereto, employees were using a skill saw tablesaw that would automaticaly restart once power was restored.  This exposed employees to possible amputation to hands or struck-by hazards from wood being thrown from the saw if it was to restart.
Recent events (1)
  • — Z (S) $0

1910.305 B02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Oct 19, 2011
Abate by
Nov 17, 2011
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    Logistic Managers Office:  On or about September 7, 2011 and times prior thereto, an  120 volt 15 amp receptacle was missing the cover.  This exposed employees to electric shock to include electocution if they contacted the conductors.
Recent events (1)
  • — Z (S) $0

View Oregon AIR National Guard 142 FW's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331067785.