Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OAK ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OAK ROOFING, INC. in 414 S. WISCONSIN, OAK PARK, IL 60302 (NAICS 238160). OSHA activity number 331078642.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch OAK Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for OAK Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
OAK ROOFING, INC.
Site address
414 S. WISCONSIN
City
OAK PARK
State
IL
ZIP
60302
Mailing
220 HEMLOCK, WOOD DALE, IL 60191
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
16
Ownership type
A

5 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 2 exposed
Issued
Nov 10, 2011
Penalty
Initial $3,300 · Current $1,650 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a)  Employees were not provided with safe access to a ladder jack scaffold platform being used at an elevation of approximately 28 feet above the ground.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1650
  • — Z (S) $3300

1926.451 G01 I

Serious Gravity 10 2 exposed
Issued
Nov 10, 2011
Penalty
Initial $4,620 · Current $2,310 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:    a) Employees were exposed to the hazard of falling while working from a ladder jack scaffold platform elevated approximately 28 feet above the ground.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2310
  • — Z (S) $4620

1926.452 K01

Serious Gravity 5 2 exposed
Issued
Nov 10, 2011
Penalty
Initial $3,300 · Current $0 Reduced
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m):    a)  Employees were exposed to the hazard of falling while working from a ladder jack scaffold platform exceeding a height of 20 feet.     No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3300

1926.502 D01

Serious Gravity 5 1 exposed
Issued
Nov 10, 2011
Abate by
Nov 14, 2011
Penalty
Initial $3,300 · Current $1,650 Reduced
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:    a) Employees were exposed to fall hazards while using personal fall arrest system components containing connectors that were not drop forged, pressed or formed steel.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1650
  • — Z (S) $3300

1926.1053 B01

Serious Gravity 5 2 exposed
Issued
Nov 10, 2011
Abate by
Nov 14, 2011
Penalty
Initial $3,300 · Current $1,662 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a)  Ladders used by employees to gain access to the working surface did not have its side rails extended at least 3 feet above the surface.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1662
  • — Z (S) $3300

View OAK Roofing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331078642.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.