WAUKESHA, WI —
OSHA Inspection: WAUKESHA FOUNDRY, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of WAUKESHA FOUNDRY, INC. in 1300 LINCOLN AVENUE, WAUKESHA, WI 53186 (NAICS 331513). OSHA activity number 331091801.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAUKESHA FOUNDRY, INC.
- Site address
- 1300 LINCOLN AVENUE
- City
- WAUKESHA
- State
- WI
- ZIP
- 53186
- Mailing
- 1300 LINCOLN AVENUE, WAUKESHA, WI 53186
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 120
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.95 G06
- Issued
- Apr 27, 2012
- Abate by
- Jun 15, 2012
- Penalty
- Initial $3,600 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : (a) The employer did not continue to provide annual audiograms as part of an effective hearing conservation program for employees exposed to to an 8-hour time weighted average noise above 85 dBA as part of an effective hearing conservation program. Employees are at increased risk of not being notified of potential hearing loss identified by standard threshold shifts of hearing function.
Recent events (2)
- — I (S) $1800
- — Z (S) $3600
1910.334 A02 II
- Issued
- Apr 27, 2012
- Abate by
- May 12, 2012
- Penalty
- Initial $5,400 · Current $100 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: (a) A portable blue Patterson flan near the wheelabrator had a dammaged electrical cord. The plug's strain releif was disattached from the cord's sheathing and the plug's grounding pin was missing. Employees were exposed to electrical shock and fire hazards. (b) A black Dayton pedestal fan had a damaged electrical cord. The plug's housing was damaged and the cord's strain relief was missing. Employees were exposed to the inner current carrying wires and possible shock.
Recent events (2)
- — I (O) $100
- — Z (S) $5400
1910.1000 A02
- Issued
- Apr 27, 2012
- Abate by
- Aug 1, 2012
- Penalty
- Initial $5,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of copper fume listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 0.1 milligrams of copper fume per cubic meter of air: (a) An air arc welder was exposed to copper fume at an 8-hour time weighted average of 0.25 mg/m3, approximately 2.5 times the limit of 0.1 mg/m3. This limit is established to prevent upper respiratory tract irritation and metal fume fever. The samples were collected on December 1, 2011 during a 442 minute sampling period. Exposure calculations include a zero increment for the 38 minutes not sampled.
Recent events (2)
- — I (S) $3000
- — Z (S) $5400
1910.1000 E
- Issued
- Apr 27, 2012
- Abate by
- Jun 13, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): (a) An air arc welder was exposed to copper fume at an 8-hour time weighted average of 0.25 mg/m3, approximately 2.5 times the limit of 0.1 mg/m3. This limit is established to prevent upper respiratory tract irritation and metal fume fever. The samples were collected on December 1, 2011 during a 442 minute sampling period. Exposure calculations include a zero increment for the 38 minutes not sampled. Feasible methods of control may include but are not limited to: 1. Improving local exhaust ventilation at the work station; 2. Employee rotation.
Recent events (15)
- — P (S) $0
- — P (S) $0
- — P (S) $0
1910.134 C01
- Issued
- Apr 27, 2012
- Abate by
- Aug 1, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) A written respiratory protection program was not developed and implemented for the air arc welder(s) over exposed to copper fume
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Waukesha Foundry, INC.
View Waukesha Foundry, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331091801.