Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. AIR FORCE 60TH LOGISTICS READINESS SQUADRON

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. AIR FORCE 60TH LOGISTICS READINESS SQUADRON in 350 HANGAR AVENUE BLDG. 549, TRAVIS AFB, CA 94535 (NAICS 928110). OSHA activity number 331917443.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. AIR Force 60TH Logistics Readiness Squadron — free Get an email when a new federal OSHA severe-injury report for U.S. AIR Force 60TH Logistics Readiness Squadron is published. One employer, no account, unsubscribe in one click.
Site address
350 HANGAR AVENUE BLDG. 549
City
TRAVIS AFB
State
CA
ZIP
94535
Mailing
540 AIRLIFT DRIVE BLDG. 381, WING 2-C, TRAVIS AFB, CA 94535
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
134
Ownership type
D

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 2 exposed
Issued
Jul 30, 2012
Abate by
Aug 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    a.   Main Bay  - Observed on or about 1/23/12, a General #31 drill press, model 34-02, serial # AF2229 did not have a guard at the point of operation.    b.   60 K Bay - Noted on or about 1/23/12, a 15"  Wilton drill press (#34),  serial #193706, was missing a guard at the point of operation.    c.  Bldg. 139, Vehicle Maintenance - Noted on or about1/20/12, the rotating chuck on a Monarch Machine Tool horizontal lathe, serial # 37339, was not provided with safeguarding to prevent unintentional contact.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 2 instances 5 exposed
Issued
Jul 30, 2012
Abate by
Aug 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a.   60K Bay - Noted on or about 1/23/12, a Dayton 8" bench grinder had a measured 1/2" gap between the tongue guard and the grinding wheel.     b.  Main Bay - Noted on or about 1/23/12, a Delta bench grinder, MD. #23-850, serial #42-85, had a 1" measured gap between the tongue guard and the abrasive wheel.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 30, 2012
Abate by
Aug 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:       a.  Bldg. 549, Storage Area - Noted on or about 1/24/12, an electrical panel board, Panel B/120V/240V, had a hole in the circuit breaker which was observed covered with cardboard and tape.  The whole measured 3"x 2" and energizes het and lighting.
Recent events (1)
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 30, 2012
Abate by
Aug 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electrical equipment safe had been made:    a.  Bldg. 139, Vehicle Maintenance, Machine Shop - Noted on or about 1/23/12, a flexible cord which energized (110V) lighting above the workbench was damaged through to the insulation.
Recent events (1)
  • — Z (S) $0

View U.S. AIR Force 60TH Logistics Readiness Squadron's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 331917443.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.