Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PIONEER DRILLING COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PIONEER DRILLING COMPANY in U S HWY. 755, OFF LA SAGUNADA RD., RIG 35, RIO GRANDE CITY, TX 78582 (NAICS 213111). OSHA activity number 333292159.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pioneer Drilling Company — free Get an email when a new federal OSHA severe-injury report for Pioneer Drilling Company is published. One employer, no account, unsubscribe in one click.
Site address
U S HWY. 755, OFF LA SAGUNADA RD., RIG 35
City
RIO GRANDE CITY
State
TX
ZIP
78582
Mailing
P O BOX 2963, CORPUS CHRISTI, TX 78403
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
11
Ownership type
A

6 citations on file for this inspection.

1910.23 A08

Serious Gravity 1 1 instance 4 exposed
Issued
Jun 1, 2012
Penalty
Initial $2,384 · Current $1,431 Reduced
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded:    Rig #35:  On or about March 22, 2012, on the off Driller's side of the rig floor there was an unguarded six inch floor hole in the walking/working surface.
Recent events (2)
  • — I (S) $1430.55
  • — Z (S) $2384.25

1910.132 E

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 1, 2012
Penalty
Initial $2,384 · Current $1,430 Reduced
29 CFR 1910.132(e): Defective or damaged personal protective equipment shall not be used:    Rig #35:  On or about March 22, 2012, on the rig floor, employee(s) climbing the derrick approximately 15 or more feet above the rig floor, wore a full body harness which was frayed and worn in areas of the belt and lanyard.
Recent events (2)
  • — I (S) $1430.4
  • — Z (S) $2384

1910.303 F02

Serious Gravity 1 2 instances 6 exposed
Issued
Jun 1, 2012
Penalty
Initial $2,384 · Current $1,431 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose:    Rig #35:  On or about March 22, 2012, circuit breakers in the electrical panel were not identified as to their function or purpose such as but not limited to the following locations:    a.  Outside wall on the Rig Manager's trailer; the Atco Structure had seventeen unidentified circuit breakers.    b.  Outside wall on the Crew Trailer; the Atco Structure had seventeen unidentified circuit breakers.
Recent events (2)
  • — I (S) $1430.55
  • — Z (S) $2384.25

1910.305 B01 I

Serious Gravity 1 1 instance 5 exposed
Issued
Jun 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i):  Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed:    Rig #35:  On or about March 22, 2012, Crew Water Closet outside wall, on the bottom of the electric box where the conductor entered, a grommet was missing, not effectively closing the opening or providing protection from abrasion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 2 instances 5 exposed
Issued
Jun 1, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:    Rig #35:  On or about March 22, 2012, in the following locations such as but not limited to:    a.  Crew Trailer, electric panel on outside wall had an opening on the bottom right side where a fitting cap was missing.    b.  Parts House, left electric panel on inside wall had two large openings on the right side of the box where knockouts were missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 3 instances 6 exposed
Issued
Jun 1, 2012
Penalty
Initial $3,179 · Current $1,907 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:    Rig #35: Employees were exposed to electrical shock due to tension not being relieved by the use of functional strain relief device from the terminal screws at the following locations:    a.  between the two mud tanks on the ground floor, at the #53 flexible electrical plug.    b.  between to two mud tanks on the ground floor, the #54 flexible electrical plug.    c.  On the outside wall of the Crew Quarters the two plug receptacle was hanging loose.
Recent events (2)
  • — I (S) $1907.4
  • — Z (S) $3179

View Pioneer Drilling Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 333292159.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.