On , OSHA opened a planned safety inspection of XTREME DRILLING AND COIL SERVICES in PERGAMOS #8-41-7-60, RIG #19, BRIGGSDALE, CO 80611 (NAICS 213111). OSHA activity number 334560158.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Xtreme Drilling and Coil Services — free Get an email when a new federal OSHA severe-injury report for Xtreme Drilling and Coil Services is published. One employer, no account, unsubscribe in one click.
Site address
PERGAMOS #8-41-7-60, RIG #19
City
BRIGGSDALE
State
CO
ZIP
80611
Mailing
16285 PARK TEN PLACE STE 650, HOUSTON, TX 77084
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
22
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm. This condition exposed the employee to struck-by hazard:     (a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611:  On and before May 22, 2012, employees utilizing pullback lines on the rig floor to lift ground pipe for the laydown and breakout used frayed and damaged pullback lines. The damage included rope distortion and broken wires. This exposed the employees to being struck by falling loads or swinging tongs upon failure of the wire rope.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

5(a)(1)

Serious Gravity 5 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards:     a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not ensure that the auxiliary escape line (geronimo line) route was clear of obstructions in that large stacks of steel material were stacked against the termination/landing point of the geronimo line. This condition exposed employees to struck-by hazards.    b) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not ensure that the auxiliary escape line (geronimo line) route was clear of obstructions in that caution tape was tied to various sections of the line. This condition exposed employees to struck-by hazards.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.23 C01

Serious Gravity 5 2 instances 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.23(c)(1): The employer failed to provide guardrails to protect personnel from a platform of 4 feet or more above ground level:    (a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer failed to provide guardrails on the V-door to protect rig personnel from falling onto the skate pipe conveyor where pipe is raised up to the rig floor o make connections. The width of the V-door is 14 inches. This condition exposed employees to fall hazards of over 10 feet.    (b) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer failed to provide guardrails on the rig floor. There were gap openings of 11-13 inches wide on the left and right side of the steps leading down from the rig floor to the draw works level.  This condition exposed employees to fall hazards of over 4 feet.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 A02 X

Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:      a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not ensure that an electrical cable running from the skate house to the flare stack was protected from accidental damage of being run over by traffic on the drilling pad. This condition exposed employees to electrical and electrocution hazards.
Recent events (2)
  • — I (O) $2100
  • — Z (S) $3500

1910.305 A02 X

Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:     (a)  Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not ensure that the power cord from the skate house to the flare stack had no tension on the joints or terminal screws. There was no form of strain relief provided to the cable extending up to the flare stack. This condition exposed the employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.132 E

Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.132(e): The employer did not ensure that defective or damaged personal protective equipment was not used:     a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not ensure that damaged hand protection was not used when working with caustic substances. A pair of gloves were found in damaged condition in the mud mixing room. This condition exposed employees to chemical burn hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1) The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace::    (a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012 the employer did not provide medical evaluations to determine if each employee's ability to use a respirator, before the employee was fit tested or required to use a respirator in the workplace.  This condition may allow employees with pre-existing medical conditions to use respirators when they are not physically capable of doing so.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.151 C

Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): The employer did not provide suitable facilities to injurious corrosive materials for quick drenching or flushing of the eyes and body within the work area for immediate emergency use:    a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not fill the eyewash resivor in the eyewash next to the mud hopper room. The cap was also missing. This condition exposed employees to chemical burn hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.307 C

Deleted Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c): The employer did not ensure that equipment in hazardous (classified) locations was intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:     (a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012 the employer did not ensure that a microwave being used in the dog house on the rig floor was intrinsically safe and approved for the Class I, Div 1 & 2 location as posted in the dog house. This condition exposed employees to explosion hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 B04 II

Other-than-serious 1 instance 7 exposed
Issued
Oct 12, 2012
Abate by
Oct 27, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(b)(4)(ii): Employers shall maintain copies of any material safety data sheets that are received with incoming shipments of the sealed containers of hazardous chemicals, shall obtain a material safety data sheet as soon as possible for sealed containers of hazardous chemicals received without a material safety data sheet if an employee requests the material safety data sheet, and shall ensure that material safety data sheets are readily accessible during each work shift to employees when they are in their work area(s):    a) Xtreme Drilling and Coil Services, Pergamos #8-41-7-60, Rig #19, Briggsdale, CO 80611: On or about May 22, 2012, the employer did not ensure that material safety data sheets were kept in a central location where they are accessible to employees in their work areas. Some material safety data sheets were found with the chemicals and some were found in a binder in the dog house. This condition exposed employees to chemical burn hazards in an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Xtreme Drilling and Coil Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 334560158.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.