Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AEF PLATING LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of AEF PLATING LLC in 4000 W URSULA AVE, MCALLEN, TX 78503 (NAICS 332813). OSHA activity number 335455788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AEF Plating LLC — free Get an email when a new federal OSHA severe-injury report for AEF Plating LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AEF PLATING LLC
Site address
4000 W URSULA AVE
City
MCALLEN
State
TX
ZIP
78503
Mailing
4000 W. URSULA AVE, MCALLEN, TX 78503
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.22 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 24, 2013
Abate by
Feb 14, 2013
Penalty
Initial $1,200 · Current $325 Reduced
29 CFR 1910.22(b)(1):     Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard:    North side of this metal plating facility, across the shop floor from the restrooms, the elevated walkway metal flooring near the eyewash/shower station was not maintained in good repair.  The walkway contained holes and openings which exposed employees to slips, trip, and falls.
Recent events (2)
  • — I (S) $325
  • — Z (S) $1200

1910.303 F02

Serious Gravity 1 3 instances 15 exposed
Issued
Jan 24, 2013
Penalty
Initial $1,200 · Current $325 Reduced
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    South side of this metal plating facility, the electrical panels inside the south side bay door did not have the circuit breaker switches labeled or identified as to which circuit they controlled in the following instances:     a.  Panel #1, 110 volts,     b.  Panel #2, 240 volts, and    c.  Panel #3, 480 volts.
Recent events (2)
  • — I (S) $325
  • — Z (S) $1200

1910.303 G02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 24, 2013
Penalty
Initial $2,000 · Current $500 Reduced
29 CFR 1910.303(g)(2)(i):     Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    An electrical box which housed a previously removed timer was left open continuously near the elevated walkway on the north side of this facility.  The box was mounted on an I-beam column and was less than 8 feet above the floor.  Employees were exposed to live conductors.