MCALLEN, TX —
OSHA Inspection: AEF PLATING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AEF PLATING LLC in 4000 WEST URSULA AVE, MCALLEN, TX 78503 (NAICS 332313). OSHA activity number 341944973.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AEF PLATING LLC
- Site address
- 4000 WEST URSULA AVE
- City
- MCALLEN
- State
- TX
- ZIP
- 78503
- Mailing
- 4000 WEST URSULA AVE, MCALLEN, TX 78503
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 17
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.133 A01
- Issued
- Apr 26, 2017
- Abate by
- May 8, 2017
- Penalty
- Initial $2,174 · Current $500 Reduced
2310
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about December 1, 2016, and at time prior thereto, at this electroplating plant production area, employees engaged in poring corrosives materials in the electroplating containers were not using adequate eye or face protection. The employer did not enforce his requirements to use eye or face protection such as, but not limited to, chemical splash goggles and/or full face shield.
Recent events (3)
- — F (O) $500
- — C (S) $2174
- — Z (S) $2174
1910.147 C07 III B
- Issued
- Apr 26, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $3,622 · Current $500 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed or whenever the employer believed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: On or about December 1, 2016, and at times prior thereto, at this electroplating plant production area, a maintenance technician who was performing maintenance and repair work on equipment deviated from the company written procedure. The employer did not retrain the operators in the correct energy control procedure.
Recent events (3)
- — F (O) $500
- — C (S) $3622
- — Z (S) $3622
1910.147 D04 I
- Issued
- Apr 26, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about December 1, 2016, and at times prior thereto, at this electroplating plant production area, a maintenance technician who was performing maintenance and repair work on equipment, was not using a Lockout or Tagout devices to isolate the hazardous energy sources. The employer did not ensure authorized employees followed company policies/procedures.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Apr 26, 2017
- Abate by
- May 8, 2017
- Penalty
- Initial $2,174 · Current $500 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about December 1, 2016, and at time prior thereto, at this electroplating plant employees were using a sludge dryer machine with unguarded sprocket wheels and chains.
Recent events (3)
- — F (O) $500
- — C (S) $2174
- — Z (S) $2174
1910.305 B01 I
- Issued
- Apr 26, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $2,173 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: On or about December 1, 2016, and times prior thereto, at this electroplating plant production area, the conduit that connected to an electrical switch panel was pulled from the switch panel, exposing the inner conductors to damage.
Recent events (3)
- — F (O) $500
- — C (S) $2173
- — Z (S) $2173
More inspections at AEF Plating LLC
View AEF Plating LLC's full OSHA safety record →
More inspections in this industry (NAICS 332313)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341944973.