Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AEF PLATING LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of AEF PLATING LLC in 4000 W URSULA AVE, MCALLEN, TX 78503 (NAICS 332813). OSHA activity number 335697819.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AEF Plating LLC — free Get an email when a new federal OSHA severe-injury report for AEF Plating LLC is published. One employer, no account, unsubscribe in one click.
Establishment
AEF PLATING LLC
Site address
4000 W URSULA AVE
City
MCALLEN
State
TX
ZIP
78503
Mailing
4000 W. URSULA AVE, MCALLEN, TX 78503
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
25
Ownership type
A

4 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 1 instance 25 exposed
Issued
Jan 24, 2013
Abate by
Mar 8, 2013
Penalty
Initial $2,000 · Current $500 Reduced
29 CFR 1910.23(c)(3):     Open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toeboard:    At this metal plating facility, employees were exposed to falls into tanks of hazardous chemicals, such as, but not limited to, Soak Cleaner, Rinse Water, Electro Clean, Hydrochloric Acid, Nitric Acid, Etch 185, Bright Dip, Sulfuric Acid, Nickel Plating, Gold Strike, Copper Strike, Silver Strike, Zinc Plating, Sour Dip, and Yellow Chromate.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2000

1910.141 D02 III

Serious Gravity 5 1 instance 12 exposed
Issued
Jan 24, 2013
Abate by
Feb 14, 2013
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.141(d)(2)(iii):     Lavatories were not provided with hand soap or similar cleansing agent:    At this workplace employees involved in plating processes use hazardous chemicals, such as, but not limited to, Gold Bath, Gold Strike, Aluma Etch 185, Soak Cleaner, Nickel Sulphamate, Luster-on Aluminescent, Bright Dip, Etch Cleaner 185, Brite Guard RP-89, Hydrochloric Acid, Sulfuric Acid, Citric Acid, Nitric Acid, and Sodium Cyanide.  The men's lavatory on the north side of this facility did not have hand soap.
Recent events (2)
  • — I (S) $400
  • — Z (S) $1600

1910.141 D02 IV

Serious Gravity 1 1 instance 12 exposed
Issued
Jan 24, 2013
Abate by
Feb 14, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(iv):     Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling:    At this workplace employees involved in metal plating processes use hazardous chemicals, such as, but not limited to, Gold Bath, Gold Strike, Aluma Etch 185, Soak Cleaner, Nickel Sulphamate, Luster-on Aluminescent, Bright Dip, Etch Cleaner 185, Brite Guard RP-89, Hydrochloric Acid, Sulfuric Acid, Citric Acid, Nitric Acid, and Sodium Cyanide.  The men's lavatory on the north side of this facility did not have a means to dry hands.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1000 C

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 24, 2013
Abate by
May 5, 2013
Penalty
Initial $2,800 · Current $750 Reduced

Hazardous substances 1430

29 CFR 1910.1000(c):     Employee(s) were exposed to an airborne concentration of Hydrogen Chloride listed in Table Z-1 in excess of the 15-minute Time Weighted Average concentration of 5 parts per million:    An employee was exposed to airborne levels of Hydrogen Chloride at 5.64 parts per million (15-minute time weighted average) while electroplating metal items.  This level is 1.128 times the OSHA ceiling limit (C) of 5.0 parts per million.  Sampling was performed on August 10, 2012 during a normal work shift for a period of 58 minutes.
Recent events (2)
  • — I (S) $750
  • — Z (S) $2800

View AEF Plating LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335697819.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.