Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ST. MARYS FOUNDRY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ST. MARYS FOUNDRY, INC. in 405 E. SOUTH ST., SAINT MARYS, OH 45885 (NAICS 331511). OSHA activity number 335677068.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ST. Marys Foundry, INC. — free Get an email when a new federal OSHA severe-injury report for ST. Marys Foundry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
405 E. SOUTH ST.
City
SAINT MARYS
State
OH
ZIP
45885
Mailing
405 E. SOUTH ST., SAINT MARYS, OH 45885
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
140
Ownership type
A

5 citations on file for this inspection.

1910.106 E02 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 31, 2012
Abate by
Jan 10, 2013
Penalty
Initial $3,060 · Current $5,967
29 CFR 1910.106(e)(2)(iv)(a): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C), were not kept in covered containers when not actually in use.    a. St. Marys Foundry, Inc. located in St. Marys, Ohio:  On or about December 21, 2012, the employer did not ensure employees working in the core room transported one gallon plastic containers of flammable alcohol based core wash in covered containers.
Recent events (2)
  • — I (S) $5967
  • — Z (S) $3060

1910.106 E02 IV D

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 31, 2012
Abate by
Jan 10, 2013
Penalty
Initial $3,825 · Current $0 Reduced
29 CFR 1910.106(e)(2)(iv)(d): Flammable or combustible liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve.     a. St. Marys Foundry, Inc. located in St. Marys, Ohio:  On or about December 21, 2012, the employer did not ensure the manually operated ball valve on the bottom of the flow coater storage tank, used to fill the flow coater reservoir, was equipped with an approved self closing valve.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3825

1910.106 E06 II

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 31, 2012
Abate by
Jan 10, 2013
Penalty
Initial $3,060 · Current $0 Reduced
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 F (37.8 C), were dispensed into containers where the nozzle and container were not electrically interconnected.     a. St. Marys Foundry, Inc. located in St. Marys, Ohio:  On or about December 21, 2012, the employer did not ensure flammable liquids such as core wash and alcohol, located in the core room, were dispensed into one gallon containers which were electrically interconnected.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3060

1910.1200 F06 II

Other-than-serious 2 instances 5 exposed
Issued
Dec 31, 2012
Abate by
Jan 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii):  The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.    a. St. Marys Foundry, Inc. located in St. Marys, Ohio:  On or about August 8, 2012, the employer did not ensure the 50 gallon storage container for the flow coater located in the core room, was labeled as to the physical and health hazards of the alcohol based material in the container.    b. St. Marys Foundry, Inc. located in St. Marys, Ohio:  On or about August 8, 2012, the employer did not ensure the small dip tank located in A core room, was labeled as to the physical and health hazards of the alcohol based material in the tank.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 D03

Other-than-serious 1 instance 2 exposed
Issued
Dec 31, 2012
Abate by
Jan 10, 2013
Penalty
Initial $3,060 · Current $1,836 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that are needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).    a. St. Marys Foundry, Inc. located in St. Marys, Ohio:  On or about December 21, 2012, the employer did not ensure employees isolated the electrical energy for the table blast machine located in the cleaning and finishing department prior to employees standing on top of the rotary table to unhook the chain sling from a large casting.
Recent events (2)
  • — I (O) $1836
  • — Z (S) $3060

View ST. Marys Foundry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335677068.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.