Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: W. E. T. CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of W. E. T. CONSTRUCTION LLC in 2825 W DIVERSEY AVE., CHICAGO, IL 60618 (NAICS 238140). OSHA activity number 335813382.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch W. E. T. Construction LLC — free Get an email when a new federal OSHA severe-injury report for W. E. T. Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2825 W DIVERSEY AVE.
City
CHICAGO
State
IL
ZIP
60618
Mailing
2420 W. PALMER STR., CHICAGO, IL 60647
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

8 citations on file for this inspection.

1926.300 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.300(b)(1):  Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:    a)  Employees were using unguarded Ryobi grinder while performing masonry tuckpointing work.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $1600

1926.451 D16

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(d)(16): The suspension scaffold power-operated hoist or manually operated hoist did not have, in addition to the normal operating brake, a braking device or locking pawl which engages automatically when a hoist makes either of the following uncontrolled movements: an instantaneous change in momentum or an accelerated overspeed.    a)  Employees were working from a two-point adjustable suspension scaffold which did not have a breaking device or locking pawl.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.451 D17

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(d)(17):  Manually operated hoists did not have a positive crank force to descend:    a)  Employees were working from a two-point adjustable suspension scaffold where the manually operated hoist did not have a positive crank force to descend.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    a)  Employees were not provided with safe access to a two-point adjustable suspension scaffold platform being used at an elevation of approximately 22 feet above the ground.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a)  Ladder used by employees to gain access to the working surface did not have its side rails extended at least 3 feet above the surface.     No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $0

1926.451 G01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system:    a)  Employees engaged in masonry work were not properly protected from hazards of falling while working from two-point adjustable suspension scaffold elevated approximately 22 feet above the ground.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $2800

1926.502 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:    a) Employees were exposed to fall hazards while using personal fall arrest system components containing connectors that were not drop forged, pressed or formed steel.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.501 B04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2012
Abate by
Aug 31, 2012
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(4)(i):  Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels by personal fall arrest systems, covers or guardrail systems erected around such holes:    a)  Employees were not protected from the hazard of falling approximately 12 feet to the lower level while performing masonry work around unguarded skylights.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2000

View W. E. T. Construction LLC's full OSHA safety record →