Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KEYSTONE STEEL STRUCTURES, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEYSTONE STEEL STRUCTURES, LLC. in 5100 MAIN STREET, EAST PETERSBURG, PA 17520 (NAICS 238120). OSHA activity number 335862827.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Keystone Steel Structures, LLC. — free Get an email when a new federal OSHA severe-injury report for Keystone Steel Structures, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
5100 MAIN STREET
City
EAST PETERSBURG
State
PA
ZIP
17520
Mailing
6285 PLANK ROAD, NARVON, PA 17555
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.453 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 5, 2012
Abate by
Sep 26, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.453(b)(2)(iv): Employees did not stand firmly on the floor of the basket, and shall not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position:    (a) Construction Site, Southern Side of Site - On or about August 21, 2012 employees were tightening bolts on structural steel beams from a Grove aerial lift and climbed the guardrails of the basket.     Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 5, 2012
Abate by
Sep 26, 2012
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.453(b)(2)(v): A body belt and a lanyard was not attached to the boom or basket when working from an aerial lift:    (a) Construction Site, Southern Side Of Site - On or about August 21, 2012 an employee was tightening bolts from a Grove aerial lift approximately 18 feet above grade and was not tied off to the basket anchor points.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1926.760 A01

Serious Gravity 10 3 instances 5 exposed
Issued
Sep 5, 2012
Abate by
Sep 26, 2012
Penalty
Initial $14,000 · Current $8,400 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems:    (a) Construction Site, Pre-engineered Building Roof - On or about August 21, 2012 employees were landing bundles of standing seam metal decking from the top of a pre-engineered metal building and were not protected from falling approximately 20 feet to grade.      (b) Construction Site, Pre-engineered Building Roof - On or about August 21 2012 employees were laying simple saver insulation on a flat roof of a pre-engineered metal building and were not protected from falling approximately 20 feet to grade.      (c) Construction Site, Pre-engineered Building Roof - On or about August 21, 2012 an employee was using a piece of equipment to seal the standing seam metal roof on top of a pre-engineered metal building and was not protected from falling approximately 16 feet to grade.     KEYSTONE STEEL STRUCTURES, INC. WAS CITED PREVIOUSLY FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1926.760(a)(1) OR ITS EQUIVALENT STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 113739189, 01, 06A AND WAS AFFIRMED AS A FINAL ORDER ON MARCH 2, 2010, WITH RESPECT TO A WORKPLACE LOCATED AT 16 MOTEL ROAD SHARTLESVILLE, PA 19554.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $8400
  • — Z (R) $14000

View Keystone Steel Structures, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 335862827.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.